This README file contains the latest information about installing IBM FAStT Storage Manager Version 7.10 for Novell NetWare. Refer to the IBM Support Website for the latest information and updated readme file. Last Update: 12/26/2002 ======================================================================= CONTENTS -------- 1.0 Overview 2.0 Change History 3.0 Installation and Setup Instructions 4.0 Configuration Information 5.0 Unattended Mode 6.0 Web Sites and Support Phone Number 7.0 Trademarks and Notices 8.0 Disclaimer 1.0 Overview ------------ 1.1 Overview ------------ This IBM FAStT Storage Manager release includes the IBM FAStT Storage Manager Version 7.10 for Novell NetWare Version 5.1. In addition, Storage Manager includes controller firmware version 4.01.02.xx and the latest NVSRAM files for IBM machine type 3526, 3542, and 3552. Refer to the IBM Support Web site for documentation and files necessary for installing IBM FAStT Storage Manager Version 7.10 for Novell NetWare. 1.2 Known Issues/Limitations ---------------------------- 1. Upgrading FAStT500 with 512MB Cache If you are upgrading from IBM FAStT Storage Manager Version 7.02 ( firmware level 04.00.02 or 04.00.03) to IBM FAStT Storage Manager Version 7.10 (firmware level 04.01.02) on a FAStT500 (machine type 3552) with 512MB of cache, you will need to stop I/O and reboot the controller before upgrading firmware followed by NVSRAM. To determine Storage Controller cache level, perform the following steps: a. On a storage management station start the client software and select a storage subsystem. b. Select Tools -> Manage Device to open the Subsystem Management Window. c. Highlight the Storage Subsystem that you are upgrading and then select Storage Subsystem -> Profile. It may take a little time for it to create the Storage Subsystem profile. d. Under the Controllers heading is an entry that displays information similar to the following example: Cache/processor size (MB): 256/32 If this setting is listed as 512/32 you will need to arrange to perform this upgrade procedure at a time that you can stop I/O to the Storage Subsystem in order to ensure a successful firmware download and installation. 2. Upgrading to 16 storage partitions on machine type 3542. Upgrading to Storage Manager 7.10 firmware version 04.01.02 and NVSRAM will enable 16 storage partitions on machine type 3542. However, the Storage Manager Client will indicate that the storage controller premium features are Out of Compliance. To clear this message, contact IBM Support and provide your feature enable identifier. You can obtain your Feature Enable Identifier from the Subsystem Management window of Storage Manager 7. Use the following procedure to obtain your Feature Enabler Identifier: Click storage subsystem -> premium features -> list Contact IBM Support to obtain a feature key file for enabling the 16 partition premium feature. Refer to the Storage Manager 7 online help for more information. 3. Error message Service Error 100 after installing Storage Manager 7.10 host-agent software. Causes of this include the following: a. The host-agent software does not find any controllers at firmware version 4.x. b. Controllers at firmware version 4.x have the access volume disabled with NVSRAM configuration settings. c. NVSRAM on a controller in a storage subsystem that you are attempting to manage has the access volume logical unit number (LUN) set to a number that is already in use by another logical drive. d. NVSRAM on controllers in a storage subsystem that you are attempting to manage contains an access volume LUN that is not supported by operating systems and installed patches (for example, the access volume is configured as LUN 31, but the operating system and service packs only support 8 LUNs). 4. The Enterprise Management Window must remain open if you want to monitor the condition of storage subsystems included in your management domain. You may want to minimize the window. If you close this window, you will not receive alert notifications. Refer to the Enterprise Management online Help for more information on alert notification options. 5. If the FAStT Controller and EXP enclosures each have a fault condition such as a failed power supply, failed fan, etc.. When the host boots up or the Host adapter device driver is loaded with the FAStT enclosures in this state, some Fibre channel logical drives may not appear. Multiplereboots of the host may show different LUNs as inaccessible. This behavior will be fixed in a future version of the FAStT Controller firmware. As this condition is caused by multiple enclosures having Unit attentions, you must fix whatever is causing the unit attention on all the enclosures, then reboot the affected hosts. See the Recovery Guru in the FAStT Storage Mangaer Client for details on the specific Unit Attentions that appear on the affected FAStT system and how to resolve them. 1.3 Enhancements ---------------- - Added Read Link Status Diagnostics support. - Corrected NVSRAM to enable background media scan without redundancy check. This setting is not changed on existing systems and must be enabled in the Storage Manager Subsystem Management console. 1.4 Prerequisites ----------------- None 1.5 Dependencies ---------------- IBM FAStT Storage Manager Version 7.10 requires machine type 3526, 3542, and 3552 controllers to have at least firmware version 4.xx.xx.xx. If the user is installing IBM FAStT Storage Manager version 7.10 onto a host with 3526 controllers that are at firmware 3.x, refer to the IBM FAStT Storage Manager 7 Migrate package located on the IBM Website at http://www.pc.ibm.com/support for instructions on upgrading the controllers to firmware 4.x. ======================================================================= 2.0 Change History ------------------ Problems fixed between IBM FAStT Storage Manager controller firmware 04.01.02.30 to 04.01.02.33(3526,3552) and 04.01.02.34(3542). --------------------------------------------------------------------- - Added Read Link Status Diagnostics support. - Volume WWN disappeared after GHS (Global Hot Spare) failure NVSRAM changes -------------- - Corrected NVSRAM to enable background media scan without redundancy check. This setting is not changed on existing systems and must be enabled in the Storage Manager Subsystem Management console. 2.1 Key Features added to IBM FAStT Storage Manager from version 7.02 to version 7.10. ---------------------------------------------------------------------- 1. Heterogeneous Hosts. The machine type 3526, 3542, or 3552 Storage Subsystem supports attaching Hosts types with different operating systems. 2. Enhanced Storage Partition Supported (128 logical drives, 16 partitions). 3. Auto logical drive transfer is activated by the I/O down an alternate controller path. 4. Storage controller enhanced diagnostics. Drive side loopback. 5. Persistent event monitoring. SNMP notification persists through the closure of Storage Manager 7 Client. 6. Configuration replication. Storage Manager 7 provides capture and replay of a configuration. 7. The command line interface automates storage management through the use of scripts. This is currently not available for the NetWare client package. 2.2 Code levels at release -------------------------- Firmware Versions: a. Machine types 3526, and 3552: Package Version 04.01.02.33 b. Machine type 3542: Package Version 04.01.02.34 b. Machine types 3526 and 3552: Bootware Version 04.01.02.03 c. Machine types 3526 and 3552: Appware Version 04.01.02.33 d. Machine type 3542: Snapware Version 04.01.02.34 NVSRAM Versions: a. Machine type 3526: Filename NV3526R710NT005 b. Machine type 3542 Models 1RX and 1RU: filename NV3542R710NT015 c. Machine type 3542 Models 2RX and 2RU: filename NV3542R710NT018 d. Machine type 3552: Filename NV3552R710NT010 SM7agent Version 07.10.15.01 SM7client Version 07.10.G5.14 SM7Uitlity version 07.10.15.03 FAStT_MSJ Version: See the IBM Support website for this package. Refer to the http://ssddom02.storage.ibm.com/techsup/webnav.nsf/support/disk IBM web page for the latest released code levels. ======================================================================= 3.0 Installation and Setup Instructions --------------------------------------- 3.1 Perform the following steps ------------------------------- - Update the IBM Netfinity Fibre Channel PCI Adapter - Update the IBM FAStT Host Adapter - Install IBM FAStT Storage Manager Version 7.10 for Novell NetWare. 1. To install or update the driver for the IBM Netfinity Fibre Channel PCI Adapter or the IBM FAStT Host Adapter: a. Install the hardware using the documentation that comes with the adapter. b. Install the IBM Netfinity Fibre Channel PCI Host Adapter driver, the IBM FAStT Host Adapter driver or the IBM FAStT FC-2 Host Bus Adapter driver located on the IBM Support Web site (refer to section 6.1). 2. Install the new Storage Manager Version 7.10 Packages. Refer to the IBM FAStT Storage Manager Version 7.10 for NetWare Installation and Support Guide for a list of installation instructions. 3. Refer to the IBM Support Web site for the latest NetWare supported host adapters, device drivers, and updated README. ======================================================================= 4.0 Configuration Information ----------------------------- 4.1 Configuration installation ------------------------------ 1. The NVSRAM in this package will now enable Media Scanning on a new configuration. If this code is installed on an existing FAStT Storage Subsystem you will need to manually enable media scanning for the subsystem and each LUN that has been created. a. In the Subsystem Management go to Storage Subsystem -> Change Media Scan Settings and select Enable background media scan and set the Duration to 30 days. a. From the Subsystem Management Window, either select the Storage Subsystem >> Change Media Scan Settings pull-down menu option or use the right mouse button to select the storage subsystem in the Logical View. Then, select Change Media Scan Settings from the pop-up menu. Result: The Change Media Scan Settings dialog is displayed. b. Check the Enable background media scan checkbox, if it is not already checked. c. Select a number in the spinner box to specify the duration (in days) of the media scan. d. Select OK. Result: The Media Scan settings for the storage subsystem are changed. The Media Scan duration specifies the number of days over which the media scan should run on the eligible logical drives. For efficiency, the storage subsystem controller will complete the media scan at a faster rate when I/O either is not occurring or is very light. Although the media scan may complete more quickly than you have specified, the storage management software will not restart a complete media scan until the specified number of days has elapsed. e. Enabling a Background Media Scan To enable a background media scan for this logical drive, select the Enable background scan check box. See the online help the IBM FAStT Storage Manager for more information on Media Scan. 2. By default the IBM FAStT Storage Manager 7.10 firmware release 04.01.02.xx does not automatically map logical drives. This means that the logical drives are not automatically presented to host systems. For a new installation, after creating new arrays and logical drives: a. If your host type is not Windows NT, create a partition with your host type and map the logical drives to this partition. b. If your host type is Windows NT, you can map your logical drives to the "Default Host Group" or create a partition with a NT host type. When upgrading from previous versions of IBM FAStT Storage Manager to version 7.10. a. If upgrading with no partitions created and you have an operating system ther than Windows NT, you will need to create a partition with your host type and map the logical drives from the "Default Host Group" to this partiton. b. If upgrading with Storage Partitions and an operating system other than Windows NT, you will need to change the host type. The host type can be changed through the Storage Manager 7.10 Storage Partitions host port. After upgrading, the default host type of a Storage Partition is Windows NT. Refer to the IBM FAStT Storage Manager online help to learn more about creating storage partitions and changing host types. 3. When you are configuring IBM machine type 3552 storage controllers as boot devices, contact IBM support for supported configurations and instructions for configuring IBM storage controllers as boot devices. 4. Running script files for specific configurations. Apply the appropriate scripts to your subsystem based on the instructions you have read in the publications or any instructions in the operating system readme file. A description of each script is shown below. - SameWWN.scr: Setup RAID controllers to have the same World Wide Names. The World Wide Names (node) will be the same for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - DifferentWWN.scr: Setup RAID controllers to have different World Wide Names. The World Wide Names (node) will be different for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - EnableDriveMigration.scr: The Enable drive migration script scans the drives for configurations when they are added to a storage system and will also attempt to use configurations found on the newly added drives. The NVSRAM default will enable drive migration. - DisableDriveMigration.scr: The disable drive migration script allows the addition of disk drives while the system is running. in addition, it identifies the drives as unused capacity regardless of past drive configuration. The NVSRAM default will enable drive migration. - 3526CTLdual.scr: Enables the detection and error reporting for missing or unresponsive controllers in a 3526 Dual RAID controller configuration. If either RAID controller is removed or not responding, it is detected and reported through theIBM FAStT Storage Manager software. The 3526 NVSRAM default is enabled to detect a missing or unresponsive alternate controller. - 3526CTLsingle.scr: This script disables the detection and error reporting of the missing alternate controller in a 3526 single RAID controller configuration. After executing this script, the IBM FAStT Storage Manager 7.10 software will not report the missing alternate RAID Controller. The machine type 3526 NVSRAM default is enabled to detect a missing alternate controller. - 3526EXPdualPS.scr: This script enables the detection and error reporting of a missing or unresponsive alternate power supply in an IBM Storage Expansion Unit configured with dual power supplies while attached to the 3526. If either Storage Expansion Unit power supply is removed or not responding, it is detected and reported through the IBM FAStT Storage Manager 7.10 software. Machine type 3526 NVSRAM default is enabled to detect a missing or unresponsive alternate power supply in an IBM Storage Expansion Unit. - 3526EXPsinglePS.scr: This script disables the detection and error reporting of a missing alternate power supply in an IBM Storage Expansion Unit configured with a single power supply and attached to the 3526. After executing this script, the IBM FAStT Storage Manager 7.10 software will not report the missing alternate power supply in an IBM Storage Expansion Unit. The 3526 NVSRAM default is enabled to detect a missing alternate power supply in an IBM Storage Expansion Unit. 4.2 Configuration Settings -------------------------- Refer to the IBM FAStT Storage Manager Version 7.10 for NetWare Installation and Support Guide for a list of specific instructions (for example, which scripts need to be applied). 4.3 Hardware Status and Information ----------------------------------- The IBM FAStT FC-2 Host Bus Adapter or IBM FAStT Host Adapter with device driver version 6.50r and the IBMSAN driver version 1.06d for MPIO failover must be loaded with new installations of IBM Machine type 3526, 3542, and 3552. 4.4 Unsupported Configurations ------------------------------ Configurations that are not supported with this level of code are listed below. 1. Fibre Channel loop environments with the IBM Netfinity Fibre Channel Hub, machine type 3523, in conjunction with the IBM Fibre Channel Switch, types 2109-S16 or 2109-S8. In this configuration, the hub is connected between the switch and the Fibre Channel RAID Controllers. 2. The IBM Netfinity Fibre Channel Hub, machine type 3523 when running Novell NetWare and are configuring for mulitpath I/O failover. ======================================================================= 5.0 Unattended Mode --------------------- None. ======================================================================= 6.0 WEB Sites and Support Phone Number -------------------------------------- 6.1 IBM TotalStorage™ Disk Storage Systems Technical Support web site: http://ssddom02.storage.ibm.com/techsup/webnav.nsf/support/disk 6.2 IBM TotalStorage™ Marketing Web Site: http://www.storage.ibm.com/hardsoft/disk/fastt/index.html 6.3 If you have any questions about this update, or problem applying the update go to the following HelpCenter World Telephone Numbers URL: http://www.ibm.com/planetwide ======================================================================= 7.0 Trademarks and Notices -------------------------- 7.1 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: IBM the e-business logo HelpCenter Microsoft, Windows, and Windows 2000 are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, and service names may be trademarks or service marks of others. 8.0 Disclaimer -------------- 8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 8.2 Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.