This README file contains the latest information about installing IBM DS4000 Storage Manager version 9.12 for Novell NetWare. Note: Novell NetWare host attachment to the IBM 1722-all models (DS4300) and the IBM 1724-all models (DS4100) requires the additional purchase of an IBM DS4300/DS4100 Novell NetWare Host Kit Option. The IBM DS4000 Novell NetWare Host Kit options contain the required IBM licensing to attach a Novell NetWare Host System to the DS4100 or DS4300 storage servers. Please contact your IBM service representative or IBM resellers for purchasing information. Refer to the IBM TotalStorage™ Support Web Site or CD for the IBM DS4000 Storage Manager version 9 Installation and Support Guides for Windows 2000/Server 2003, Netware, ESX Server, and Linux. This guide along with the DS4000 Storage Manager program Online Help provide the installation and support information. Last Update: 3/14/2005 Products Supported: ---------------------------------------------------------------- | New Model | Old Model | Machine Type | Model | |------------|-----------|--------------|------------------------| | DS4500 | FAStT 900 | 1742 | 90X, 90U | |------------|-----------|--------------|------------------------| | DS4400 | FAStT 700 | 1742 | 1RX, 1RU | |------------|-----------|--------------|------------------------| | DS4300 | FAStT 600 | 1722 | 6LX, 6LU, 60X and 60U | |------------|-----------|--------------|------------------------| | DS4100 | FAStT 100 | 1724 | 100, 1SC | |----------- |-----------|--------------|------------------------| | N/A | FAStT 500 | 3552 | 1RX, 1RU | |------------|-----------|--------------|------------------------| | N/A | FAStT 200 | 3542 | 1RX, 1RU, 2RX and 2RU | ------------ --------------------------------------------------- Note: - The DS4000 Storage Server controller firmware version 05.40.xx.xx and earlier along with its associated NVSRAM files should not be loaded into DS4000 storage servers connected to DS4000 EXP100 drive expansion enclosures. - For the DS4300 with Standard(base) or Turbo options, the DS4400 and the DS4500 storage servers connected to the DS4000 EXP100 drive expansion enclosures, the controller firmware version 06.1x.xx.xx and its associated NVSRAM file must be used. In addition, the DS4100 storage server with standard (base) option is now supporting the controller firmware version 06.12.xx.xx or later. - For the DS4100 storage servers with Single Controller option, the controller firmware version 05.42.xx.xx and its associated NVSRAM file must be used. Do not attempt to download the controller firmware version 06.1x.xx.xx into these DS4100 storage server with single controller option models. - For the DS4300 storage servers with Single Controller option, the controller firmware version 05.34.xx.xx and its associated NVSRAM file must be used. Do not attempt to download the controller firmware version 06.1x.xx.xx into these DS4300 storage server with single controller option models. CONTENTS ----------------- 1.0 Overview 2.0 Change History 2.1 Code levels at release 3.0 Installation and Setup Instructions 4.0 Configuration Information 5.0 Unattended Mode 6.0 Web Sites and Support Phone Number 7.0 Trademarks and Notices 8.0 Disclaimer ======================================================================= 1.0 Overview ------------------- This IBM DS4000 Storage Manager release includes the IBM DS4000 Storage Manager Version 9.12 for Novell NetWare. It is required for managing the DS4000 storage servers - the DS4100 with standard (base) option, the DS4300 with standard (base) or Turbo options, the DS4400 and the DS4500 - with controller firmware version 06.12.xx.xx installed. The Netware directory contains the files necessary for installing the IBM DS4000 Storage Manager version 9 software for NetWare. The controller Firmware and NVSRAM files are located in the DS4000 Storage Manager Version 9.12 Support for Microsoft Windows OSes CD under the Firmware and NVSRAM directories. Please Refer to the IBM TotalStorage™ Support Web Site or the DS4000 Storage Manager Version 9.12 Support for Novell Netware CD for the IBM DS4000 Storage Manager version 9 Installation and Support Guides for Windows 2000/Server 2003, Netware, ESX Server, and Linux. This guide along with the DS4000 Storage Manager program Online Help provide the installation and support information. In addition, the Docs directory in the DS4000 Storage Manager Version 9.12 Support for Novell Netware CD-ROM also contains others DS4000 publications that provide helpful information. IMPORTANT: This release of IBM DS4000 Storage Manager host software supports all DS4000 Storage Servers with general released firmware versions from 04.01.xx.xx up to 06.12.xx.xx. Refer to the IBM DS4000 Support Web Site for latest DS4000 controller firmware and NVSRAM files for IBM machine types 1722, 1724, 1742, 3542 and 3552. The following table shows the first four digits of the latest controller firmware versions that are currently available for various models of the DS4000 storage servers. --------------------------------------------------- | | Controller firmware version | |------------------|--------------------------------| | DS4000 | | | Storage Server | | | Model | | |------------------|--------------------------------| | DS4500 (1742) | 06.12.xx.xx | |------------------|--------------------------------| | DS4400 (1742) | 06.12.xx.xx | |------------------|--------------------------------| | DS4300 Turbo | 06.12.xx.xx | | Option (1722) | | |------------------|--------------------------------| | DS4300 | 06.12.xx.xx | | Standard Option | | | (1722) | | |------------------|--------------------------------| | DS4300 Single | 05.34.xx.xx | | Controller Opt. | (for DS4300 SCU | | (1722) | only) | |------------------|--------------------------------| | DS4100 (1724) | 06.12.xx.xx | | | | |------------------|--------------------------------| | DS4100 Single | 05.42.xx.xx | | Controller Opt. | (for DS4100 SCU | | (1724) | only) | |------------------|--------------------------------| | FAStT500 (3552) | 05.30.xx.xx | |------------------|--------------------------------| | FAStT200 (3542) | 05.30.xx.xx | --------------------------------------------------- New features that are introduced with the controller firmware version 06.12.xx.xx or later will not be available for any DS4000 storage server controllers without the controller firmware version 06.10.xx.xx installed. ======================================================================= 1.1 Known Issues/Limitations ----------------------------------------- IMPORTANT: The listed limitations are cumulative. However, they are listed by the DS4000 storage subsystem controller firmware and Storage Manager host software releases to indicate which controller firmware and Storage Manager host software release that they were first seen and documented. New limitations with Storage Manager version 9.12.xx.08 and DS4000 controller firmware version 06.12.03.xx release 1. Do not cut and paste the information in the DS4000 Storage Manager online help into the DS4000 Storage Manager script command window or into the text file that will be used as input for the SMcli script engine. Extra space may be inserted in the required parameter names which will cause error(s) during the script command execution. (267873) 2. In the configuration that have both SATA-technology drives (EXP100) and Fibre-Channel technology drives (EXP700/EXP710/DS4100) behind the same DS4000 storage server, do not download drives firmware to both SATA-technology drives and Fibre-Channel(FC) technology drives at the same time. Download the drive firmware to drives of a single drive technology (either SATA or FC) at a time. 3. Currently, IBM does not support Gold key Premium Feature as a chargeable upgrade. The Gold key Premium Feature is enable or disable depending on the DS4000 storage server models. 4. The Asynchronous Remote Mirroring utility, asyncRVMUtil, is not supported. This utility is used to automatically synchronize the logical drives in the Remote Mirroring pairs. Please contact IBM representatives or resellers for the support of this utility in the future. Limitations with Storage Manager version 9.10.xx.05 and DS4000 controller firmware version 06.10.11.xx release 1. Do not update the DS4000 storage server controller firmware to version 06.1x.xx.xx from versions 05.4x.xx.xx or earlier if the exp700 esm firmware of the attached exp700 was not at 9326. If the EXP700 ESM firmware is earlier than the 9326 versions, the EXP700 enclosure and the installed drives may not be displayed in the DS4000 subsystem management window after the controller firmware is upgraded to 06.1x.xx.xx version. The workaround is to update the EXP700 ESM firmware to the 9326 version first before upgrading the controller firmware to version 06.1x.xx.xx. (260160 - 82841) 2. When connecting the EXP100 or EXP700 drive expansion enclosures, one must set the single digit (X1) of the enclosure ID to unique values. This is to prevent the possibility that one of the drives in the EXP100 or EXP700 enclosures be assigned the same ALPA as the DS4000 controller blade under certain DS4000 storage subsystem reboot scenarios. (261188) Limitations with Storage Manager version 9.10.xx.02 and DS4000 controller firmware version 06.10.06.xx release 1. Certain Storage Manager Command Line Interface (SMcli) commands require double-quotes as part of the syntax. The NetWare operating system removes the double-quotes causing the scripts to fail. The workaround is to pass the command through to SMcli using a text file if the double quotes are required as part of the command. The quotes will be preserved and the script will execute correctly. 2. On newly installed versions of NetWare, hot_add will not run if it is not in the search path in the autoexec.ncf file. Edit the autoexec.ncf file and add the following to the search path: search add sys:\ After adding the information to the search path, be sure to save the file and restart the computer. 3. The DS4000 Copy Service RVM is not supported at this time for the DS4100 and the DS4300 storage server with Standard or Single Controller options. 4. An NSS volume mapped to a Windows client is rendered inaccessible after a "cluster leave" command on one cluster node caused the NSS Pool to be migrated to the other cluster node. 5. In the Storage Manager version 9 client Subsystem Management window, the preferred owner of a defined logical drive can not be changed if the logical drive is managed by the preferred owner/controller. There is no work-around. If the drive is currently managed by a non- preferred owner/controller, one can change the currently managed non- preferred owner/controller into currently managed preferred owner/controller. 6. Concurrent firmware download (downloading firmware/NVSRAM to the DS4000 storage server controllers with IOs to the host servers) is not supported when upgrading the controller firmware from a 05.xx.xx.xx version to a 06.1x.xx.xx version. ALL IOs must be stopped during the version 06.1x.xx.xx controller firmware upgrade from a 05.xx.xx.xx version. 7. Do not pull or insert drives during the drive firmware download. In addition, ALL IOs must also be stopped during the drive firmware download. Otherwise, drives may be shown as missing, unavailable or failed. 8. Controller diagnostics will not run in a DS4000 storage server with single controller. 9. When instructed to remove and reinsert or to replace a hard drive, wait at least 70 seconds before inserting either the removed existing drive or the new drive into the drive slot. Then, wait up to 3 minutes for the drive to be spined up, recognized by the DS4000 storage subsystem and displayed in the Subsystem Management window before repeating the process for another hard drive. There is no work-around. Similarly, wait at least 70 seconds before reinserting either the removed existing ESM module or the new ESM module into the empty ESM slot in the EXP drive expansion enclosure. Then, wait up to 3 minutes for the ESM CRU to be recognized by the DS4000 storage subsystem and displayed in the Subsystem Management window before repeating the process for another ESM. There is no work-around. 10. Staged firmware and NVSRAM download function is not available on the DS4400 (machine type 1742) models with firmware 06.1x.00.00 in conjunction with IBM Storage Manager 09.1x.xx.xx. Limitations with Storage Manager version 8.4x.xx.xx (and earlier) and DS4000 controller firmware version 05.4x.xx.xx (and earlier) releases 1. When trying to unload the Storage Manager Agent it will not completely unload. After running the "Java -killxxx" command you must then type "unload Java" at the server console. You may then restart the Novell GUI console by typing "startx" at the server console. 2. When trying to configure disks in Console One you will first need to allow the disks to finish synchronizing in Storage Manager prior to trying to create your disks in Console One. 3. When creating a Remote Mirror of a base logical drive, in the case where a FlashCopy of the base logical drive has already been created, the following restriction applies. If the Remote Mirror relationship is created while the base logical drive is receiving I/O, the FlashCopy logical drive will be failed. The work around is to quiesce I/O to the base logical drive while you are creating the remote mirror relationship. Alternatively, if the Remote Mirror relationship is created before creating the FlashCopy logical drive, the FlashCopy logical drive will not be failed. 4. When managing the DS4000 Storage Servers with firmware version 05.3x.xx.xx, the Help window of the Subsystem Management window may not be displayed correctly the topics that are listed as result of executing a full text search. 5. When migrating array(s) from a dual controller DS4000 storage server to a single controller DS4000 storage server, you must first set the preferred owner of the to-be-migrated array(s) to be controller A before inserting it into the drive slots of a single controller DS4000 storage server. Otherwise, the array(s) will not be added to the single controller DS4000 storage server correctly which might cause problems. 6. When managing a single controller DS4000 Storage Server model, do not use the menu option - Configuration->Automatic... - in the Subsystem Management window to create LUNs. You might not be able to access or manage LUNs that are created this way. 7. You must suspend all I/O while ESM firmware downloads if you select multiple enclosures for downloading ESM firmware. If you select only one enclosure for download at a time, you can download ESM firmware with I/Os. However, IBM recommends that you suspend all I/O activity to perform firmware upgrades. 8. If the EXP100 ESM firmware version is 953x or earlier, no IOs are allowed during the duration that the EXP100 ESMs are being updated with new firmware, including clustering reservation checking IOs. 9. After you replace a controller with a new controller in the single controller models of DS4000 storage servers, the premium features become unauthorized and are out of compliance. Any premium features not supported by the firmware of the new controller are unavailable. The work-around is to upgrade the firmware in the new controller to the same level as the removed controller and re-enable the premium features using the key files that you were provided when the premium feature was originally enabled. 10. When you migrating drive Customer Replaceable Units (CRUs) from multiple DS4000 storage servers into a single destination DS4000 storage servers, all of the drive CRUs from the same DS4000 storage server should be moved as a ‘set’ into the new destination DS4000 storage server. Before moving the next ‘set’ of drive CRUs, ensure that all of the drive CRUs for a single ‘set’ have been moved to the destination DS4000 storage server. If drive CRUs are not moved as a ‘set’ to the destination DS4000 storage servers, the newly relocated array may not appear in the Subsystem Management window. 11. Enclosure IDs may be listed incorrectly in the Subsystem Management window, even if the Enclosure ID switch settings appear to be correct. This is because of the physical design and movement of the Enclosure ID switch, it is possible to leave the switch in a “dead zone” between ID numbers, which will return an incorrect Enclosure ID (this value is 0 in most cases) to the storage management software. When setting the Enclosure ID, ensure that the switch has actuated completely and has settled where the value is clearly visible in the viewing window. 12. To download controller firmware, you must select the drive where the firmware is located. If the drive you select does not respond, the File Selection dialog box will revert to the A: drive and display an error message that drive A: is not ready if there are no media in drive A:. 13. The DS4000 storage server when configured with the DS4000 EXP100 SATA Drive Expansion Unit is currently reporting a higher frequency of informational events such as Destination Driver Events (DDEs) and FibreChannel link up/down events ... in the DS4000 Controller event log compared to the DS4000 storage server configured with Fibre Channel drives. Slower response times of SATA disk drives compared to Fibre Channel disk drives cause higher I/O retries from the DS4000 storage server controllers, resulting in a greater number of informational events logged. In addition, the number of information events reported in the DS4000 storage server event log will also grow in proportion to the increase in I/Os to the Logical Drives. In all cases, the DS4000 storage server controller will always successfully service the timeout I/O on the subsequent retries. 14. When saving the DS4000 storage server event log entries, it may take up to several minutes to save all entries in the event log depending on the DS4000 management workstation resources. However, the DS4000 Storage Manager client GUI will show the completion of the event log saving almost instantly. The work around is to check the file size of the file that the event log entries are saved periodically; if the file size does not change, the event log saving is completed. 15. Do not perform other storage management tasks, such as creating or deleting logical drives, reconstructing arrays, and so on, while downloading the DS4000 storage server controller firmware and DS4000 EXP ESM firmware. It is recommended that you close all storage management sessions (other than the session that you use to upgrade the firmware) to the DS4000 storage server that you plan to update. 16. Inter-operability with tape devices is supported on separate HBA and switch zones. ======================================================================= 1.3 Enhancements --------------------------- ATTENTION: New features that are introduced with the DS4000 Storage Manager version 9.12 host software will not be available for any DS4000 storage server controllers without the controller firmware version 06.12.xx.xx installed. The DS4000 storage server controller firmware version 6.12.xx.xx is available for the following DS4000 storage server only - the DS4100, the DS4300 with standard(base) or Turbo option, the DS4400 and the DS4500. Please contact your IBM service representative or IBM resellers for availability of additional DS4000 storage server models support with controller firmware version 6.12.xx.xx in the future. A summary list of the new features that are introduced with the DS4000 Storage Manager version 9.12 host software for Netware operating systems in conjunction with the DS4000 storage server controller firmware version 06.12.xx.xx is as followed: 1. Support for the FC/SATA intermix premium feature enable via a premium feature key file. A premium key file, instead of a NVSRAM file, is now required to enable the FC/SATA premium feature intermix in a DS4000 storage server. 2. Support for the DS4100 with standard(base) option with controller firmware v06.xx.xx.xx code thread. No new premium features are available at this time for the DS4100 storage server with the controller firmware version 6.12.xx.xx. 3. New DS4000 host-software installation wizard that will automatically install the appropriate host-software components depending on the select server type (ie. host or management-station.) 4. Serviceability Enhancement - the ability to extract SMART data for SATA-technology drives. 5. Usability Enhancement - Added Wizard to Storage Manager SMclient to aid users with Storage Partitioning creation with Hosts, Adapters, and mappings. Added Task Assistant to Storage Manager which helps guide users through common task wizards for both the Enterprise and Subsystem management tasks. Please refer to the New Features section of the IBM DS4000 Storage Manager version 9 Installation and Support Guide for Windows 2000/Server 2003, Netware, ESX Server, and Linux for additional information about the IBM DS4000 Storage Manager version 9.12 enhancements. ======================================================================= 1.4 Prerequisites ------------------------ 1. JAVA JVM version 1.4.2 2. NetWare 6 with Support Pack 4, Netware 6.5 with support pack 2 3. "Direct connection of the DS4300 to a host system running Microsoft Windows, Novell NetWare or x86 Linux is only supported using the IBM DS4000 FC2-133 Host Bus Adapter (HBA), IBM option part number 24P0960 or feature code 2104 with the last 6 digits of the 13 digit serial number of the HBA is H21160 or higher. For example, if the serial number is FFC0308H21161, the last 6 digits will be H21161, which indicates that this HBA meets the DS4300 direct connect prerequisite. In addition, direct connect to the NAS 300G (Machine Type 5196) Model G27 or Model G02 containing Feature Code 3706 is only supported if the last 6 digits of the 13 digit serial number of the HBA is above H21160. ======================================================================= 1.5 Dependencies -------------------------- IMPORTANT: 1. DS4000 STORAGE SERVER CONTROLLER FIRMWARE VERSION 06.10.XX.XX REQUIRES THAT THE FIRMWARE VERSION OF AN ATTACHED EXP100 ENVIRONMENTAL SERVICE MODULE (ESM) BE AT VERSION 955X OR HIGHER. IT IS NOT POSSIBLE TO UPGRADE EXP100 ESM FIRMWARE VERSIONS THROUGH 953X TO VERSION 955X. TO DETERMINE THE FIRMWARE LEVEL OF AN EXP100 ESM, IDENTIFY THE PRODUCT LABEL LOCATED AT THE REAR OF THE EXP100 ENCLOSURE. ONLY LABELS ON WHICH THE FIELD REPLACEABLE UNIT (FRU) PART NUMBER READS 25R0156 POSITIVELY INDICATE THAT AN ESM MODULE IS RUNNING FIRMWARE VERSION 955X OR HIGHER. IF THERE IS NO LABEL OR THE PART NUMBER ON THE LABEL DOES NOT READ 25R0156, THE ESM MAY STILL HAVE THE FIRMWARE VERSION 955X OR HIGHER IF IT HAD BEEN PREVIOUSLY UPGRADED. IF NECESSARY, CONTACT YOUR IBM REPRESENTATIVE, SUPPORT, OR RESELLER FOR ASSISTANCE. 2. DS4000 STORAGE SERVER CONTROLLER FIRMWARE VERSION 06.10.XX.XX REQUIRES THAT THE FIRMWARE VERSION OF AN ATTACHED EXP700 ENVIRONMENTAL SERVICE MODULE (ESM) BE AT VERSION 9326 OR HIGHER. IF THE EXP700 ESM FIRMWARE IS EARLIER THAN THE 9326 VERSIONS, THE EXP700 ENCLOSURE AND THE INSTALLED DRIVES MAY NOT BE DISPLAYED IN THE DS4000 SUBSYSTEM MANAGEMENT WINDOW AFTER THE CONTROLLER FIRMWARE IS UPGRADED. 3. CURRENTLY, THE ONLY DS4000 STORAGE SERVERS THAT ARE SUPPORTED BY THE 06.12.XX.XX CONTROLLER FIRMWARE VERSION ARE THE DS4100 WITH STANDARD (BASE) OPTION, THE DS4300 WITH STANDARD (BASE) OR TURBO OPTIONS, THE DS4400 AND THE DS4500. DO NOT DOWNLOAD THIS CONTROLLER FIRMWARE ON ANY OTHER DS4000 STORAGE SERVER. THERE IS NOT ANY CHECKING FOR THIS RESTRICTION INSIDE THE STORAGE MANAGER CLIENT PROGRAM. 4. Always check the README files (especially the Dependencies section) that are packaged together with the firmware files for any required minimum firmware level requirements and the firmware download sequence for the DS4000 drive expansion enclosure ESM, the DS4000 storage server controller and the hard drive firmware. 5. If the managed DS4000 storage server had the FC/SATA intermix premium feature enable, do not upgrade the controller firmware from version 06.10.xx.xx to version 06.12.xx.xx until a FC/SATA intermix premium feature key file is generated and available. Once the controller firmware is upgraded to version 06.12.xx.xx, the FC/SATA intermix premium feature will be shown as out-of-compliance and the FC/SATA intermix premium feature key file is required to re-enable the feature. When the FC/SATA intermix premium feature is in out-of- compliance state, LUNs management functions like creations, deletions and modifications will not be operational. Please refer to the FC/SATA intermix premium feature activation card that was IBM DS4000 Storage Manager version 09.1x.xx.xx provides full management support for IBM machine types 3552 and 3542 storage controllers that have at least firmware version 04.01.xx.xx, IBM Machine type 1742 storage controllers that have at least firmware version 05.00.04.xx, IBM Machine type 1742-900 and Machine type 1722 storage controllers that have at least firmware version 05.3x.xx.xx or IBM Machine type 1724 storage controllers that have at least firmware version 05.42.xx.xx. The only IBM DS4000 Storage Manager version 09.1x.xx.xx management function supported on DS4000 Storage Servers with controller firmware version 04.xx.xx.xx up to 04.00.02.xx is controller firmware and NVSRAM download. ======================================================================= 2.0 Change History ---------------------------- Version 09.12.xx.08 dated 03/18/2005 - Support the DS4000 Storage Server controller firmware version 06.12.xx.xx - Support the controller firmware version 06.12.xx.xx installed in the DS4100 storage servers with standard option - Support FC/SATA intermix premium feature activation via premium key file - Added wizard and task assistants in the Storage Manager Client to guide users through common DS4000 storage server management tasks. - Fix defect 268261 - Cannot create Arrays with < 6 drives when using full capacity with Storage Manager 9.10.G5.05 - Fix defect 261426 - Email alert notification mail does not conform to RFC 821 and 822 rules. Placement with a semi-colon at the end of email recipient address causes SMTP mail servers to reject the email as spam. Version 09.10.xx.05 dated 01/17/2005 (for DS4100 base option support) - Support the controller firmware version 06.10.xx.xx or higher for the DS4300 storage servers with standard option. Support for the attachment of EXP710 drive enclosures to the DS4300 storage servers with standard option Version 09.10.xx.05 dated 11/24/2004 - Support for the DS4000 FC/SATA storage expansion enclosure intermix option - Enhance the DS4000 Enhance Remote Mirroring Global Copy and Global mirroring functions - Support for the attachment of EXP100 SATA storage expansion enclosures to the DS4400 storage server - Support the DS4100 storage server with Single Controller option - Support for the increase in the maximum number of EXP100 drive expansion enclosures that can be connected to a DS4100 storage server. The maximum EXP100 drive enclosure that can be connected to DS4100 is now 7 instead of 4 - 254966 ( 81363) DS4000 controllers do not agree on configurations - 256414 ( 81441) Cannot create new LUN using FSM 9.1 / FW 6.1 - 259611 ( 82674) Cannot install SM 9.10 because of a defect in Storage Manager host software uninstall - 261681 download allenclosures firmware cmd not working correctly. - hlpct_53466 ( 80833) tcp port scan causes controllers to reboot - change MIB file name to SM9_10.MIB Version 09.10.xx.02 dated August 31, 2004 - Enhance Remote Mirroring support. Besides Metro Mirroring, IBM DS4000 Storage Manager version 9.1x also supports Global Copy and Global Mirroring Remote Mirror options. - Parallel hard drive firmware download. - Staged controller firmware download. - Full command-line SMcli support. - Improve DS4000 storage manager client Subsystem Management GUI - Adding additional diagnostic features - Drive Channel status, hard drive sector failure list. Version 08.42.xx.02 dated 08/27/2004 - Support the new DS4000 storage server model - DS4100 (machine type 1724 - model 100.) The DS4100 storage server controller firmware version must be 05.42.07.xx or later. The EXP100 ESM firmware version must be 955x or higher. Note: Do not use IBMSAN failover driver in the Netware servers that has mapped LUNs from the DS4100 storage server. Version 08.42.G5.00 dated 06/18/2004 - Support for DS4300 and DS4500 storage servers in configurations with EXP100 drive expansion enclosures. Version 08.40.G5.04 dated 04/05/2004 - Support for DS4300 single controller model 6LX, 6LU. ======================================================================= 2.1 Key Features added to latest release of IBM DS4000 Storage Manager host software. ------------------------------------------------------------------------- - Support the DS4000 Storage Server controller firmware version 06.12.xx.xx - Support the controller firmware version 06.12.xx.xx installed in the DS4100 storage servers with standard option - Support FC/SATA intermix premium feature activation via premium key file - Added wizard and task assistants in the Storage Manager Client to guide users through common DS4000 storage server management tasks. - Fix defect 268261 - Cannot create Arrays with < 6 drives when using full capacity with Storage Manager 9.10.G5.05 - Fix defect 261426 - Email alert notification mail does not conform to RFC 821 and 822 rules. Placement with a semi-colon at the end of email recipient address causes SMTP mail servers to reject the email as spam. ======================================================================= 2.2 Code levels at time of release are as follows ------------------------------------------------------------------ 1. IBM DS4000 Storage Manager Installer wizard version: 09.12.15.08 (SMIA-NETW-09.12.15.08.zip) 2. There are not any separate installation packages for the IBM DS4000 Storage Manager version 9 Client, Agent and Utilities software packages as in previous releases of the IBM DS4000 Storage Manager host software for Netware OS. The Storage Manager Agent and Utilities software packages are software installation options that can be selected for installing together with the IBM DS4000 Storage Manager Client host software. The DS4000 Storage Manager Installer wizard will install the following version of the host-software packages: a. IBM DS4000 Storage Manager Client version: 09.12.G5.04 b. IBM DS4000 Storage Manager Agent version: 09.12.15.00 c. IBM DS4000 Storage Manager Utilities version: 09.12.15.00 Refer to the http://www.ibm.com/servers/storage/support/disk IBM TotalStorage™ Disk Storage Systems Technical Support web site for the latest supported host adapters, device drivers, and updated readme. ======================================================================= 3.0 Installation and Setup Instructions ---------------------------------------------------- 3.1 Step-by-step instructions for this code update are as follows ---------------------------------------------------------------------------------------- Note: The web-download Storage Manager version 9.12 host software package must be first unpacked (unzipped) into a user-defined directory. Then, go to this directory, locate the Netware directory to access the Storage Manager version 9.12 host software installer wizard. 1. Install and update the driver for the IBM DS4000 Host Adapter. a. Install the hardware by using the instructions that come with the adapter. b. Install the IBM DS4000 Host Adapter driver by using the instructions provided in the readme.txt file located in the Host_Adapter directory on this installation CD. c. Install the Novell Netware native fail-over device driver. Note: IBMSAN fail-over device drive is not supported for NW 6 with SP4 or higher and NW 6.5. 2. Install the new Storage Manager version 9 software. If there is previous version (7.x, 8.x or 9.10) of the IBM DS4000 Storage Manager host software installed in the system, uninstall it before installing the new version of the storage manager host software. Note: Use the install.ncf file to start the DS4000 storage manager version 9 host software installation instead of the product.ni file as in the previous releases of DS4000 storage manager host software. Refer to the IBM TotalStorage DS4000 Storage Manager Version 9 Installation and Support Guide for Windows 2000/Server 2003, Netware, ESX Server, and Linux for detailed uninstalled and installed instructions. 3. If the managed DS4000 storage server had the FC/SATA intermix premium feature enable, do not continue with the next step until a FC/SATA intermix premium feature key file is generated and available. Once the controller firmware is upgraded to version 06.12.xx.xx from version 06.10.xx.xx, the FC/SATA intermix premium feature will be shown as out-of-compliance and the FC/SATA intermix premium feature key file is required to re-enable the feature. When the FC/SATA intermix premium feature is in out-of-compliance state, LUNs management functions like creations, deletions and modifications will not be operational. Please refer to the FC/SATA intermix premium feature activation card that was shipped with the FC/SATA intermix premium feature kit for instructions to generate the required premium key file. 4. Upgrade the DS4000 storage server firmware in the following order - the DS4000 drive expansion enclosure ESM code, the DS4000 storage server controller firmware and NVSRAM and then the hard drive firmware code. Refer to the IBM DS4000 Storage Manager version 9 Installation and Support Guide for Windows 2000/Server 2003, Netware, ESX Server, and Linux or the online help in the Subsystem Management window for detailed instructions. ATTENTION: Always check the README files (especially the Dependencies section) that are packaged together with the firmware files for any required minimum firmware level requirements and the firmware download sequence for the DS4000 drive expansion enclosure ESM, the DS4000 storage server controller and the hard drive firmware. 5. (if applicable) Re-enable the FC/SATA intermix premium feature using the premium key file. Refer to the http://www.ibm.com/servers/storage/support/disk IBM TotalStorage™ Disk Storage Systems Technical Support web site for the the latest DS4000 Storage Manager host software, the DS4000 controllers firmware, the drive expansion enclosure ESM firmware and the hard disk drive code. ======================================================================= 3.2 Refer to the Host_Adapter directory on this installation CD for the applicable drivers. --------------------------------------------------------------------- Refer to the IBM Support Web Site for the latest supported host adapters, device drivers, and updated readme. At this time, the supported drivers are as follows: 1. IBM DS4000 Host Adapter device driver for NetWare version 6.51d for IBM DS4000 FC HBAs and 6.80F for IBM DS4000 FC2 and FC2-133 HBAs. 2. LSIMPE.CDM version 1.00.04 dated May 3th, 2004 or later 3. MM.NLM version 3.20.07 dated December 10th, 2003 or later. 4. NWPA.NLM version 3.20.01 dated December 1st, 2003 or later. Note: The IBMSAN.CDM version 106e dated November 4th, 2002 is not supported for NW6 SP3 or later and for NW6.5. In addition, this driver will not recognize LUNs from the DS4100 storage server. This driver is for NW 6 SP2 and earlier and NW 5.1 SP6 only. ======================================================================= 3.3 Helpful Hints ------------------ 1. The DS4000 Storage Management dialog windows may be displayed cropped without the vertical and horizontal scroll bars. Just move the mouse pointer over the edge of the window until the mouse pointer change to window resize pointer, left click and hold to grip the window edge to resize it. 2. If you are unable to see the maximum number of drives during Automatic Configuration, you should be able to use Manual Configuration to select individual drives and select the maximum number of drives allowed. 3. Depending on the storage subsystem that you have purchased, you may have to purchase the DS4000 storage partitioning premium feature option or an option to upgrade the number of supported partitions in a storage subsystem. Please see IBM Marketing representatives or IBM resellers for more information. - IBM DS4100 storage subsystem (machine type 1724): The standard configuration does not have the DS4000 storage partitioning premium enabled. Four partition, eight partition, sixteen and an upgrade from four to eight partition storage partitioning premium feature options can be purchased. - IBM DS4300 storage subsystem (machine type 1722): The standard configuration does not have the DS4300 storage partitioning premium enabled. Four partition, eight partition, sixteen and an upgrade from four to eight partition storage partitioning premium feature options can be purchased. The IBM DS4300 Turbo option comes with 8 partition storage partitioning premium option installed. An upgrade to 64 partitions can be purchased for the IBM DS4300 Turbo option. - IBM FAStT200 (machine type 3542): The standard configuration has 16 partition storage partitioning premium option installed. No additional storage partitioning premium feature options can be purchased for these storage subsystems. - IBM FAStT500 and DS4400 storage subsystems (machine type 3552 and 1742 - models 1RU and 1RX, respectively): The standard configuration has 64 partition storage partitioning premium option installed. No additional storage partitioning premium feature options can be purchased for these storage subsystems. - IBM DS4500 storage subsystem (machine type 1742 - models 90X and 90U): The standard configuration has 16 partition storage partitioning premium option installed. An upgrade from 16 to 64 partition storage partitioning premium feature option can be purchased. 4. Fabric topology zoning requirement. To avoid possible problem at the host level, it is best practice that all Fibre Channel (FC) Switches must be zoned such that a single FC host bus adapter can only access one controller per storage array. In addition, this zoning requirement also ensures the maximum number of host connections can be seen and log into the controller FC host port. This is because if a FC HBA port is seen by both controller A and B host ports, it will be counted as two host connections to the storage subsystem - one for controller A port and one for controller B port. Note: The DS4000 Storage Servers DS4500, DS4400 and FAStT500 (IBM machine type 1742 and 3552) have two ports per controller - one per minihub slot. The DS4000 Storage Servers DS4300 (IBM machine type 1722) and DS4100 (IBM machine type 1724) have two ports per controller. The DS4000 storage Server FAStT200 (IBM machine type 3542) has only one port per controller. 5. The DS4000 controller host ports or the Fibre Channel HBA ports can not be connected to a Cisco FC switch ports with "trunking" enable. You might encounter failover and failback problems if you do not change the Cisco FC switch port to "non-trunking" using the following procedure: a. Launch the Cicso FC switch Device Manager GUI. b. Select one or more ports by a single click. c. Right click the port(s) and select Configure, a new window pops up d. Select the "Trunk Config" tab from this window, a new window opens e. In this window under Admin, select the "non-trunk" radio button, it is set to auto by default. f. Refresh the entire fabric. 6. When making serial connections to the DS4000 storage controller, the baud rate is recommended to be set at either 38200 or 57600. Note: Do not make any connections to the DS4000 storage server serial ports unless it is instructed by IBM Support. Incorrect use of the serial port might result in lost of configuration, and possibly, data. 7. All drive enclosures on any given loop should have complete unique ID's assigned to them. For example, in a maximum configured DS4500 storage server, enclosures on one redundant drive loop should be assigned with id's 10-17 and enclosures on the second drive loop should be assigned with id's 20-27. Enclosures id's 00 ~ 09 should not be used and enclosure id's with the same single digit such as 11 and 21 should not be used on the same drive loop. 8. The ideal configuration for SATA drives is one drive in each EXP per array, one logical drive per array and one OS disk partition per logical drive. This configuration minimizes the random head movements that increase stress on the SATA drives. As the number of drive locations to which the heads have to move increases, application performance and drive reliability may be impacted. If more logical drives are configured, but not all of them used simultaneously, some of the randomness can be avoided. SATA drives are best used for long sequential reads and writes. 9. IBM recommends at least one hot spare per EXP100 drive expansion enclosure. A total of 15 hot-spares can be defined per DS4000 storage server configuration. 10. Starting with the DS4000 Storage Manager (SM) host software version 9.12 or later, the Storage Manager client script window looks for the files with the file type of ".script" as the possible script command files. In the previous versions of the DS4000 Storage Manager host software, the script window looks for the file type ".scr" instead. (i.e. enableAVT.script for 9.12 or later vs. enableAVT.scr for pre-9.12) ======================================================================= 4.0 Configuration Information ---------------------------------------- 4.1 Configuration Settings ------------------------------------ 1. By default, the IBM DS4000 Storage Manager 9.1x firmware does not automatically map logical drives when the IBM DS4000 storage partitioning premium feature is enabled. This means that the logical drives after being created are not automatically presented to the host systems. a. For a new installation, after creating new arrays and logical drives, create a storage partition with the host type of Netware-failover (when using the Novell native fail-over driver) or Netware-IBMSAN (when using the IBMSAN fail-over driver) and map the logical drives to this partition. b. If you are upgrading the NVSRAM with Storage Partitions and the host system OS was other than Microsoft Windows NT is accessing the default host group, you will need to change the default host type to match the host system OS. After upgrading the NVSRAM, the default host type is reset to Windows non-clustered (SP5 or higher). Refer to the IBM DS4000 Storage Manager online help to learn more about creating storage partitions and changing host types. 2. When you are configuring IBM machine type 1722, 1724, 1742, 3542, or 3552 storage controllers as boot devices, contact IBM support for supported configurations and instructions for configuring IBM storage controllers as boot devices. 3. When you are configuring IBM machine type 1722, 1742 or 3552 storage servers in clustered Remote Mirror configurations, contact IBM support for supported cluster configurations and instructions for configuring IBM storage controllers in clustered Remote Mirror configurations. ======================================================================= 4.3 Hardware status and information -------------------------------------------------- For more information, refer to the IBM TotalStorage™ Disk Storage Systems Technical Support web site. ======================================================================= 4.3 Unsupported configurations ------------------------------------------- The following lists configurations that are currently not being supported with IBM DS4000 Storage Manager Version 9.12. 1. The DS4100 (machine type 1724) storage server does not support the attachment of the DS4000 EXP710 and EXP700 (FC) drive expansion enclosure. Please contact IBM representatives or resellers for the availability of such support in the future. 2. The DS4100 with Single Controller option does not support the attachment of the DS4000 EXP100 drive expansion enclosures. 3. The DS4300 storage server with Single Controller option does not support the controller firmware version 06.1x.xx.xx. The correct firmware version for these DS4300 storage server models is 05.34.xx.xx. 4. The DS4100 storage server with Single Controller option does not support the controller firmware version 06.1x.xx.xx. The correct firmware version for these DS4300 storage server models is 05.42.xx.xx. 5. Fibre Channel loop environments with the IBM Fibre Channel Hub, machine type 3523 and 3534, in conjunction with the IBM Fibre Channel Switch, machine types 2109-S16, 2109-F16 or 2109-S8. In this configuration, the hub is connected between the switch and the IBM Fibre Channel RAID Controllers. 6. The IBM Fibre Channel hub, machine type 3523, connected to IBM machine type 1742, 3542 and 3552. 7. A configuration in which a server with only one FC host bus adapter connects directly to any DS4000 Storage Server with dual controllers is not supported. The supported configuration is the one in which the server with only one FC host bus adapter connects to both controller ports of any DS4000 Storage Server with dual controllers via Fibre Channel (FC) switch (SAN-attached configuration.) ======================================================================= 5.0 Unattended Mode -------------------------------- None. ======================================================================= 6.0 WEB Sites and Support Phone Number ---------------------------------------- 6.1 IBM TotalStorage™ Disk Storage Systems Technical Support web site: http://www.ibm.com/servers/storage/support/disk/ 6.2 IBM TotalStorage™ Marketing Web Site: http://www.ibm.com/servers/storage/disk 6.3 If you have any questions about this update, or problem applying the update go to the following HelpCenter World Telephone Numbers URL: http://www.ibm.com/planetwide IMPORTANT: You should download the latest version of the DS4000 Storage Manager host software, the DS4000 storage server controller firmware, the DS4000 drive expansion enclosure ESM firmware and the drive firmware at the time of the initial installation and when product updates become available. To be notified of important product updates, you must first register at the IBM Support and Download Web site: www-1.ibm.com/servers/storage/disk/ Perform the following steps to register at the IBM Support and Download Web site: 1. Click on My Support in the Additional Support box in the right side of the DS4000 Support web page. 2. The Sign In window displays. Either enter your IBM ID and Password in the sign in area to sign in and proceed to step 6 or, if you are not currently registered with the site, click Register Now. 3. The My IBM Registration window Step 1 of 2 opens. Enter the appropriate information and click Continue to get to the second My IBM Registration window. 4. In the My IBM Registration window Step 2 of 2, enter the appropriate information and click Submit to register. 5. The My IBM Registration windows opens with the following message, “Thank you for registering with ibm.com. Continue to explore ibm.com as a registered user.” Click Edit Profile in the My IBM box on the right side of the window. 6. The My Support window opens. Click Add Products to add products to your profile. 7. Use the pull-down menus to choose the appropriate DS4000 storage server and expansion enclosures that you want to add to your profile. To add the product to your profile, select the appropriate box or boxes next to the product names and click Add Product. 8. Once the product or products are added to your profile, click Subscribe to Email folder tab 9. Select Storage in the pull down menu. Select Please send these documents by weekly email and select Downloads and drivers and Flashes to receive important information about product updates. Click Updates. 10. Click Sign Out to log out of My Support. ======================================================================= 7.0 Trademarks and Notices ---------------------------- 7.1 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: IBM FAStT TotalStorage™ the e-business logo xSeries HelpCenter Linux is a registered trademark of Linus Torvalds. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United states, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. ======================================================================= 8.0 Disclaimer ---------------- 8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 8.2 Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.