This README file contains the latest information about the IBM TotalStorage™ FAStT Storage Server controller firmware version 05.4x.xx.xx. Refer to the IBM TotalStorage™ Support Web Site or CD for the IBM FAStT Storage Manager version 8.4x (Intel or Unix Operating Systems) Installation and Support Guides for firmware and NVSRAM download instructions. For other related publications (refer to Related Publications in the installation and support guide) and the latest information and updated readme file. Last Update: 04/06/2004 Products Supported: --------------------------------------------------- | | Machine Type | Model | |-----------|--------------|------------------------| | FAStT 900 | 1742 | 90X , 90U | |-----------|--------------|------------------------| | FAStT 700 | 1742 | 1RX, 1RU | |-----------|--------------|------------------------| | FAStT 600 | 1722 | 60U , 60X | --------------------------------------------------- Note: The controller firmware and NVSRAM files that are part of this IBM TotalStorage™ FAStT release should not be loaded into FAStT storage servers connected to FAStT EXP100 drive expansion enclosures. For FAStT storage servers connected to FAStT EXP100 drive expansion enclosures, the controller firmware and NVSRAM files that are part of the IBM TotalStorage™ FAStT Storage Server controller firmware version 05.41.xx.x release must be used instead. ======================================================================= CONTENTS -------- 1.0 Overview 2.0 Change History 3.0 Installation and Setup Instructions 4.0 Configuration Information 5.0 Unattended Mode 6.0 Web Sites and Support Phone Number 7.0 Trademarks and Notices 8.0 Disclaimer ======================================================================= 1.0 Overview -------------- The IBM TotalStorage™ FAStT Storage Server controller firmware version 05.40.xx.x release includes the FAStT Storage Server controller firmware and NVSRAM files for upgrading the following IBM machine types - 1722 (models 60X and 60U), 1742 (all models). The IBM TotalStorage FAStT Storage Manager version 8.4x Installation and Support Guide for Intel-based Operating System Environments or the IBM TotalStorage FAStT Storage Manager version 8.4x Installation and Support Guide for AIX, HP-UX and Solaris are available on IBM's Support Web Site as a downloadable Portable Document Format (PDF) file. In addition, IBM FAStT Copy Services premium features - FlashCopy, VolumeCopy and Remote Mirror - are options purchased separately. The Copy Services premium features require a minimum FAStT storage server controller firmware installed. ------------------------------------------------------------------ | Premium Feature | Required controller firmware version | |--------------------------|---------------------------------------| | FlashCopy | 05.00.04.xx or higher | |--------------------------|---------------------------------------| | VolumeCopy | 05.40.xx.xx or higher | |--------------------------|---------------------------------------| | Remote Mirror | 05.20.0x.xx or higher | ------------------------------------------------------------------ The FAStT storage partitioning premium feature is standard on all IBM FAStT storage subsystems with the exception of the IBM FAStT600 (machine type 1722 with Standard option) storage subsystem. Please contact IBM Marketing representatives or IBM resellers if you want to purchase the IBM FAStT storage partitioning premium feature option for it. The Turbo option of the IBM FAStT600 is shipped with the IBM FAStT storage partitioning premium feature enabled (8 partitions). The IBM FAStT Storage Manager controller firmware version 05.40.xx.xx is a purchase upgrade for IBM machine types 1722 and 1742 with controller firmware version 05.3x.xx.xx and earlier installed. Please contact your IBM service representatives or IBM resellers for purchasing info. This version 8.4 upgrade of IBM FAStT Storage Manager software has controller firmware for IBM machine types 1722-60X/60U (with Turbo or Standard option), 1742-1RX/1RU and 1742-90X/90U only. The FAStT Storage Controller firmware 05.40.xx.xx for this release is not available for IBM machine types 3542 and 3552. However, the host software of IBM FAStT Storage Manager 8.4 will manage all FAStT storage server with the controller firmware 04.00.02.xx or newer. But, any new features and updates that are introduced in this FAStT Storage Manager version 8.4 will not be available for any FAStT storage server controllers without the controller firmware version 05.40.xx.xx installed. Refer to the IBM Support Web Site for the latest Firmware and NVSRAM files for the IBM FAStT Storage Subsystems. http://www.ibm.com/storage/support/fastt ======================================================================= 1.1 Limitations --------------------- 1. Storage Manager prompts you for a password if all hard disk drives are removed from the storage subsystem. After removing all drives from a storage subsystem (or not powering on drives and only the controller), the IBM FAStT Storage Manager software will prompt you for a password when trying to start the software or trying to perform protected operations. Any password entered will fail. Password information is stored on a reserved area of each hard disk drive on the storage subsystem. Each drive stores a mirrored copy of the password data. When there are no drives in the storage subsystem, the storage management software does not find the password data when you attempt password protected operations. Add one drive to the storage subsystem and retry the operation. Since the RAID controller unit should not be powered on until the expansion units are attached and powered on, this should be done by powering off the RAID controller unit, properly attaching all expansion units (with drives installed), to the RAID controller unit and powering them on, and then powering the RAID controller unit back on. At this point the storage subsystems can be re-discovered and managed using the IBM FAStT Storage Manager 8.2 software. 2. Auto LUN/Array Transfer is not enable for Microsoft Windows, IBM AIX and SUN Solaris OS's. If a controller fails over arrays to the alternate controller and the failed controller is replaced and brought back online, the arrays do not automatically transfer to the preferred controller. This must be done manually by selecting the redistributing arrays menu option in the storage subsystem window of the IBM FAStT storage manager client program. 3. Display issues when using 256 color settings. A brownish hash pattern is displayed on the windows and in online help when running in 256 color mode. Run the Storage Manager 8 application in a higher display mode. 4. The FAStT Storage Management dialog windows may be displayed cropped without the vertical and horizontal scroll bars. Just move the mouse pointer over the edge of the window until the mouse pointer change to window resize pointer, left click and hold to grip the window edge to resize it. 5. If you get "Error 21 - The Operation cannot complete because a ... is in progress" error when you issue a Subsystem Management command from the IBM FAStT Storage Manager Client, the command may be cached. If the command is cached, the IBM FAStT Storage Manager Client will run the command as soon as the controller resources are available. Wait for at least ten minutes and check to see whether the command has been run. If not, re-attempt the command. 6. If the controller in the IBM FAStT Storage Server with firmware 05.3x.xx.xx is connected to a SAN with more than 64 host connections per controller port that can log into the controllers, one must either use the switch zoning function or rearrange the SAN connections so that only the maximum number of host connections can be seen and log into the controller. The FAStT Storage Subsystem FAStT900, FAStT700 (IBM machine type 1742) have two ports per controller - one per minihub slot. The FAStT Storage FAStT600 (IBM machine type 1722) has two ports per controller. 7. The IBM FAStT Storage Server hardware and software is designed to have redundant paths from the host system to ensure the availability of storage. However, it is possible to connect a single host adapter from the host system to one of the controller minihubs and then connect this minihub to the minihub of the other controller. This configuration will create a FC-AL loop between the host adapter and the two IBM FAStT Storage Server controllers and no redundant path to the host system. When you connect the two minihubs together, always connect the "IN" port of one minihub to the "OUT" port of the other minihub or vice versa. Do not connect the "IN" port of one to the "IN" port of the other minihub or the "OUT" port of one minihub to the "OUT" port of the other minihub. 8. When creating a Remote Mirror of a base volume the following restriction applies. First, you have created a snapshot of a base volume and the base volume is receiving I/O. Second, you decide to create a mirror relationship, using the base volume as the primary volume in the mirrored pair. As you create the mirror relationship, the snapshot volume is failed. The work around is to stop I/O to the base volume while you are creating the mirror relationship. Alternatively, if the mirror relationship is created before creating the snapshot volume, this will not happen. 9. Only logical drives that are configured as "Basic Disks" in the Windows Disk Management folder can have Flashcopy made. The Flashcopy of a logical drive configured as "Dynamic Disk" type will always failed by the FAStT storage server when it is added to the host server. 10. The FAStT Storage Manager version 8.4 does not support Veritas DMP in Windows operating system environment. Please contact IBM representatives or resellers for the availability of support. ======================================================================= 1.2 Enhancements ----------------- - Support for IBM TotalStorage FAStT600 Turbo Option Fibre Channel Storage Server. - Support for up to 256 LUN mapping per host server (depending on the operating system). - Persistent Reservations. - Logical Drive Copy. - Support for IBM TotalStorage FAStT600 Fibre Channel Storage Server. The machine type and models of the FAStT 600 storage server is 1722 and 60X and 60U, respectively. - Support for IBM TotalStorage FAStT900 Fibre Channel Storage Server. The machine type and models of the FAStT 900 storage server is 1742 and 90X and 90U, respectively. - Support for online Environmental Services Monitor (ESM) card firmware downloads. The ESM cards are customer replaceable unit (CRU) components in the IBM FAStT storage expansion units. The ESM firmware can be updated while the storage subsystem receives I/Os from the servers. - Support for offline Fibre Channel hard drive firmware and mode page downloads. The I/O from the servers must be suspended during the duration of the hard drive firmware and mode page download. - Support for Media Scan without Parity repairs - Support for forcibly disabling Fibre Channel drive-level write caching - Support the controller state dump function for diagnostics ======================================================================= 1.3 Prerequisites ------------------ N/A ======================================================================= 1.4 Dependencies ----------------- IBM FAStT Storage Manager version 08.4x.xx.xx provides full management support for IBM machine types 3552 and 3542 storage controllers that have at least firmware version 04.00.02.xx, IBM Machine type 1742-900 and 1742 storage controllers that have at least firmware version 05.00.04.xx or IBM Machine type 1722 storage controllers that have at least firmware version 05.3x.xx.xx. The only IBM FAStT Storage Manager version 08.4x.xx.xx supported management function on controllers with firmware version 04.xx.xx.xx to 04.xx.01.xx is controller firmware and NVSRAM download. ======================================================================= 2.0 Change History ----------------------------- ====================================================================== 2.1 Key Features added to IBM FAStT Storage Server controller firmware version 05.4x.xx.xx. This is a maintenance release of the FAStT Storage Server controller firmware and NVSRAM. The fix list is as followed: 73777 (LHA) Drive firmware downloads fail 75567 (CL #75479) Memory leak beginning in Sonoran 4. 69535 TD_PT1103 Incorrect name for component location in Event Log. 69629 Downloading controller firmware with offline volumes causes unfinished download pr 69872 (CL #69467) TD_PT1086 RLS baseline date after new device insertion is incorrect. 70105 (CL #70048) TD_PT1195 Diagnostic path to controller report down falsely 70891 (CL #70586) TD_PT1277 Drive size reported incorrectly for a closed drive 71206 tray number reported incorrectly during discovery 70561 (CL #68445) C219318 CMVC 217537: Data miscompare while doing online controller firmware downloads 70772 (CL #68894) Analysis of a MEL log shows Dacstore Scrub is repeating on a volume group 71782 (RW #68268) (CL #67670) Can't create volume if drive sizes are similar 72339 CMVC-hlpct_42401 Error importing a 7.3 Gig FlashCopy LUN 72676 (CL #70100) SMclient GUI reports array needs attention, but guru reports 72712 (CL #72672) TD_PT1461 Ancient I/O during sysReboots 72768 (CL #72449) controllers repeatedly panic during M1 -> S3 FW upgrade 69052 Drives not assigned to proper loop on 2882 69204 (CL #68807) Profile not reporting correct unconfigured capacity on volume group - Modify the NVSRAM file to disable Cache Sync in the W2K het host region. ======================================================================= 2.2 Code levels at time of release are as follows ------------------------------------------------- 1. Storage Controller Firmware versions: a. FAStT 900: FW_05401101_05400400 b. FAStT 700: FW_05401101_05400400 c. FAStT 600: SNAP_05401101 2. Storage Controller NVSRAM versions: a. FAStT 900: N1742F900R840V03 b. FAStT 700: N1742F700R840V04 d. FAStT 600: N1722F600R840V05 Refer to the following IBM TotalStorage™ Disk Storage Systems Technical Support web site for the latest released code levels. http://www.ibm.com/storage/support/fastt ======================================================================= 3.0 Installation and Setup Instructions ----------------------------------------- 3.1 Important: You must install the firmware update prior to downloading the NVSRAM update. To download firmware, do the following: a. Open the Subsystem Management window. b. Click Storage Subsystem => Download => Firmware. Follow the online instructions. To download NVSRAM, do the following: a. Open the Subsystem Management window. b. Click Storage Subsystem => Download => NVSRAM. Follow the online instructions. 3.2 After the controller firmware and NVSRAM is updated, consider checking the IBM TotalStorage™ Disk Storage Systems Technical Support web site for the latest released drive expansion enclosure ESM firmware and the Fibre Channel hard drive firmware. To download drive expansion ESM firmware, do the following: a. Open the Subsystem Management window. b. Click Advanced => Download => Environmental(ESM) Card Firmware. Follow the online instructions. To download hard disk drive firmware, do the following: a. Open the Subsystem Management window. b. Click Advanced => Download => Drive Firmware. Follow the online instructions. ======================================================================= 3.2 Helpful Hints ------------------ 1. If you are unable to see the maximum number of drives during Automatic Configuration, you should be able to use Manual Configuration to select individual drives and select the maximum number of drives allowed. 2. Depending on the storage subsystem that you have purchased, you may have to purchase the FAST storage partitioning premium feature option or an option to upgrade the number of supported partitions in a storage subsystem. Please see IBM Marketing representatives or IBM resellers for more information. - IBM FAStT600 storage subsystem (machine type 1722): The standard configuration does not have the FAST storage partitioning premium enabled. Four partition, eight partition and an upgrade from four to eight partition storage partitioning premium feature options can be purchased. - IBM FAStT700 storage subsystems (machine type 1742 - models 1RU and 1RX): The standard configuration has 64 partitions storage partitioning premium option installed. No additional storage partitioning premium feature options can be purchased for these storage subsystems. - IBM FAStT900 storage subsystem (machine type 1742 - models 90X and 90U): The standard configuration has 16 partition storage partitioning premium option installed. An upgrade from 16 to 64 partition storage partitioning premium feature option can be purchased. ======================================================================= 4.0 Configuration Information ----------------------------- 4.1 Configuration Settings -------------------------- 1. By default the IBM FAStT Storage Manager 8.4 firmware does not automatically map logical drives if storage partitioning feature is enabled. This means that the logical drives are not automatically presented to host systems. For a new installation, after creating new arrays and logical drives; a. If your host type is not Windows NT, create a partition with your host type and map the logical drives to this partition. b. If your host type is Windows NT, you can map your logical drives to the "Default Host Group" or create a partition with a NT host type. When upgrading from previous versions of IBM FAStT Storage Manager to version 8.4. a. If upgrading with no partitions created and you have an operating system other than Windows NT, you will need to create a partition with your host type and map the logical drives from the "Default Host Group" to this partition. b. If upgrading with Storage Partitions and an operating system other than Windows NT is accessing the default host group, you will need to change the default host type. After upgrading, the default host type is reset to Windows NT. Refer to the IBM FAStT Storage Manager online help to learn more about creating storage partitions and changing host types. 2. When you are configuring IBM machine type 1722, 1742, 3542 or 3552 storage subsystems as boot devices, contact IBM support for supported configurations and instructions for configuring LUNs in the IBM storage subsystems as boot devices. 3. Running script files for specific configurations. Apply the appropriate scripts to your subsystem based on the instructions you have read in the publications or any instructions in the operating system readme file. A description of each script is shown below. - SameWWN.scr: Setup RAID controllers to have the same World Wide Names. The World Wide Names (node) will be the same for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - DifferentWWN.scr: Setup RAID controllers to have different World Wide Names. The World Wide Names (node) will be different for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - EnableDriveMigration.scr: The Enable drive migration script scans the drives for configurations when they are added to a storage system and will also attempt to use configurations found on the newly added drives. The NVSRAM default will enable drive migration. - DisableDriveMigration.scr: The disable drive migration script allows the addition of disk drives while the system is running. in addition, it identifies the drives as unused capacity regardless of past drive configuration. The NVSRAM default will enable drive migration. 4. When you are configuring IBM machine type 1742 or 3552 storage controllers in host cluster Remote Mirror configurations, contact IBM support for supported host cluster configurations and instructions for configuring IBM storage controllers in clustered Remote Mirror configurations. ======================================================================= 4.2 Unsupported configurations ------------------------------ The following lists configurations that are currently not being supported with IBM FAStT Storage Manager 8.4. 1. Fibre Channel loop environments with the IBM Fibre Channel Hub, machine type 3523 and 3534, in conjunction with the IBM Fibre Channel Switch, machine types 2109-S16, 2109-F16 or 2109-S8. In this configuration, the hub is connected between the switch and the IBM Fibre Channel RAID Controllers. 2. The IBM Fibre Channel Hub, machine type 3523, connected to IBM machine type 1722, 1742, 3542 and 3552. ======================================================================= 5.0 Unattended Mode --------------------- N/A ======================================================================= 6.0 WEB Sites and Support Phone Number ---------------------------------------- 6.1 IBM TotalStorage™ Disk Storage Systems Technical Support web site: http://www.ibm.com/storage/support/fastt 6.2 IBM TotalStorage™ Marketing Web Site: http://www.storage.ibm.com/hardsoft/disk/fastt/index.html 6.3 If you have any questions about this update, or problem applying the update go to the following HelpCenter World Telephone Numbers URL: http://www.ibm.com/planetwide ======================================================================= 7.0 Trademarks and Notices ---------------------------- 7.1 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: IBM FAStT ToTalStorage™ the e-business logo xSeries pSeries HelpCenter Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United states, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Other company, product, and service names may be trademarks or service marks of others. ======================================================================= 8.0 Disclaimer ---------------- 8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 8.2 Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.