IBM Advanced System Management Device Driver Diskette version 1.20 CONTENTS -------- 1.0 Overview 2.0 Change History 3.0 System Management Device Driver installation instructions 4.0 Stopping the Netfinity Manager application program 5.0 Web Sites and Support Phone Number 6.0 Trademarks and Notices 7.0 Disclaimer 1.0 Overview ------------- This diskette contains device drivers for the following service processor hardware: - Advanced System Management PCI Adapter card - Advanced System Management Processor which is part of the planar board on specific models of IBM servers - Automatic Server Restart (ASR) which is built onto the planar board of specific models of IBM servers - Remote Supervisor Adapter 2.0 Change History ------------------- 2.1 Advanced System Management Device Driver version 1.19 to 1.20 For all server models running Windows 2000 or Windows NT-4: Changes have been made to the device driver installation instructions in this readme.txt file. Added support for future IBM eservers. 2.2 Advanced System Management Device Driver version 1.18 to 1.19 For Netfinity Server models 4500R, 5000, 5100, 5500, 5500-M10, 5500-M20, 5600, 6000R, 7000-M10, 7100, 7600 or 8500R running SCO Unixware: Added support for non interactive installation and removal of the device driver. For more information, please refer to the installation instructions for SCO Unixware in this document. For Netfinity Server models 4500R, 5000, 5100, 5500, 5500-M10, 5500-M20, 5600, 6000R, 7100, or 7600 that have the IBM Advanced System Management PCI Adapter installed, and are running Windows 2000: A cosmetic change was made to the IBM Advanced System Management PCI Adapter item in the System Devices list under Device Manager to remove the "yellow bang" symbol that incorrectly indicated the card was not operating properly. 2.3 Advanced System Management Device Driver version 1.17 to 1.18 For IBM eserver xSeries 220 servers running Windows 2000, Windows NT 4 or Netware: Added support for Automatic Server Restart hardware, which restarts a server with an operating system that has stopped or crashed. Added support for future IBM servers. 2.4 Advanced System Management Device Driver version 1.16 to 1.17 For Netfinity Server models 4500R, 5000, 5100, 5500, 5500-M10, 5500-M20, 5600, 6000R, 7000-M10, 7100, 7600 or 8500R running SCO Unixware: When the service processor device drivers are installed in SCO Unixware, the installation script modified the permissions of /tmp directory. This problem has been corrected in this release. Added support for future IBM servers. 3.0 System Management Device Driver installation instructions -------------------------------------------------------------- Note: The Netfinity Manager application program must be stopped before any of these service processor device drivers can be installed. Please refer to the section 4.0 of this document for instructions on how to stop the Netfinity Manager program. By following the installation instructions shown below, the correct System Management Device Driver will be automatically installed onto your Netfinity Server. If the installation is being done from this diskette, insert this diskette into the server's floppy diskette drive, bring up a command prompt window, screen, or session, and enter one of the following commands. The examples shown below assume the floppy drive is A:. If the installation is being done from the Advanced Systems Management Utilities CD-ROM, insert this CD-ROM into the server's CD-ROM drive, bring up a command prompt window, screen, or session, and enter one of the following commands. The examples shown below assume the CD ROM drive is D:. For OS/2, type: A:\OS2\SETUP (if installation is from a diskette) or D:\DD\OS2\SETUP (if installation is from a CD-ROM) Follow the directions that appear on the screen For Windows 2000: For the following list of servers with the Netfinity Advanced System Management Processor hardware, correct driver installation will require that Windows 2000 be installed after ensuring that the system BIOS is at the following level or higher: Netfinity 5000: MOJT36A Netfinity 5500: KIJT73A Netfinity 5500 M10: KIJT73A Netfinity 5500 M20: KQJT19A If a BIOS update is required, use the latest BIOS image files and instructions for installation, which can be found at http://www.pc.ibm.com/support. The Windows 2000 System Management Driver files are included on the ServerGuide installation CDs for Windows 2000 and will be installed automatically when Windows 2000 is installed. Installation from the install diskette will only be required if Windows 2000 is installed without using ServerGuide, or if the System Management Driver is manually uninstalled. For installation under Windows 2000, you can choose from one of the following three methods. 1 The following set of instructions apply if you use the automatic initiation of the "Hardware Wizard" by Windows. * Click "Next" on the "Found New Hardware Wizard" screen. * The hardware will automatically be detected as an "Unknown" device for the Netfinity Advanced System Management Processor, or "Other PCI bridge device" for the Netfinity Advanced System Management PCI Adapter hardware. * Select "Search for a suitable driver for my device" and click "Next". * Insert the diskette or CD-ROM and check the appropriate medium (floppy / CD) on the screen. Click "Next" to continue. * Hardware wizard will find the matching driver for your hardware (asmpa.inf or asmp.inf). * Follow instructions on screen until the "Finish" message appears. Click "Finish" to complete the installation of the driver. * NOTE: The Hardware Wizard will repeat this installation process two times to install additional drivers for the Netfinity System Management PCI Adapter. 2 The following set of instructions apply when you choose to install the driver manually. * Open the "Device Manager". This may be done by right clicking on the "My Computer" icon on the desktop, selecting "Properties", and then selecting "Device Manager". * In the "System Devices", look for an "Unknown" device or "Other PCI bridge device". The hardware has automatically been detected as an "Unknown" device for the Netfinity Advanced System Management Processor, or "Other PCI bridge device" for the Netfinity Advanced System Management PCI Adapter hardware. The driver must be installed for this detected device. * Highlight the appropriate device and right click to select "Properties". Click on the "Driver" tab, and select "Update Driver". * Select "Search for a suitable driver for my device" and click "Next". * Insert the diskette or CD-ROM and check the appropriate medium (floppy / CD) on the screen. Click "Next" to continue. * Hardware wizard will find the matching driver for your hardware (asmpa.inf or asmp.inf). * Follow instructions on screen until the "Finish" message appears. Click "Finish" to complete the installation of the driver. * NOTE: The Hardware Wizard will repeat this installation process two times to install additional drivers for the Netfinity System Management PCI Adapter. 3 The following set of instructions apply when you choose to update the driver for the Netfinity Advanced System Management. PCI Adapter or the IBM Remote Supervisor hardware. * Open the "Device Manager". This may be done by right clicking on the "My Computer" icon on the desktop, selecting "Properties", and then selecting "Device Manager". * In the "Multifunction Adapters", look for the "IBM Netfinity Adavanced System Management ..." or the IBM Remote Supervisor+..." device. * Highlight the appropriate device and right click to select "Uninstall", and follow the user prompts to uninstall the driver. * The system should then be restarted. Windows should prompt the user for a restart at this point. * After restarting, the Hardware wizard will start. Click "Next" on the Hardware wizard screen. * Select "Search for a suitable driver for my device" and click "Next". * Insert the diskette or CD-ROM and check the appropriate medium (floppy / CD) on the screen. Click "Next" to continue. * Hardware wizard will find the matching driver for your hardware. If Hardware wizard finds it's cached copy of the driver description (oem*.inf) and no other suitable drivers, then click "Next" to refresh the driver from the diskette or CD-ROM. If Hardware wizard finds it's cached copy of the driver description and also finds another suitable driver then it will display a message that begins "The wizard also found other drivers that are suitable...", and will display the this option: "_ Install one of the other drivers" In that case check this option and click "Next". A list of suitable drivers will appear. Select "asmpa.inf" from the list and continue. * Follow instructions on screen until the "Finish" message appears. Click "Finish" to complete the installation of the driver. * The install process will now be repeated two times to install additional drivers for the IBM Netfinity System Management PCI Adapter, or be repeated three times to install drivers for the IBM Remote Supervisor. If the option: "_ Install one of the other drivers" appears for any of these driver installations, check that option and select the driver file that was found on the supplied diskette or CD-ROM. * The system should then be restarted. Windows should prompt the user for a restart at this point. For Windows NT 4: NOTE: The NT-4 operating system must have Service Pack 3 or higher installed in order for these drivers to work properly. There are 2 methods you can choose from when installing the Windows NT 4 System Management Drivers. 1 The unattended method will install the drivers and accept default values for any screen prompts that would otherwise appear. The user will be prompted if an error occurs during installation. For an unattended installation of the drivers: * Open a Command prompt * If installing from a diskette, type: A:\NT\SETUP -q * If installing from a CD ROM, type: D:\DD\NT\SETUP -q * Follow the directions that appear on the screen 2 The normal method will prompt the user with instructions and wait for the user to answer before continuing with the installation. For a normal installation of the drivers: * Open a Command prompt * If installing form a diskette, type: A:\NT\SETUP * If installing from a CD ROM, type: D:\DD\NT\SETUP * Follow the directions that appear on the screen If the NT 4 System Management Drivers are being upgraded on a system that has Universal Manageability Services (UMS) running, then the easiest method to upgrade the driver is to follow the steps listed below. * Click on the Start Menu, then select Settings, then select Control Panel * In the Control Panel window, double-click the Devices icon * Scroll down to the entry that shows ibmspw and highlight it * Click the Startup... button on the right side of the window * In the Startup window, select the Disabled radio button and then click the OK button * Close the Devices and Control Panel windows and reboot the machine. * After the machine has rebooted, install the System Management Drivers using one of the two installation steps described above. After the drivers are installed, they will automatically be re-enabled. For Novell NetWare type one of the following lines in the System Console Session: LOAD A:\NETWARE\SETUP (if installation is from a diskette) or LOAD D:\DD\NETWARE\SETUP (if installation is from a CD ROM) Follow the directions that appear on the screen For SCO/UnixWare: There are three methods you can choose from when installing the SCO/UnixWare System Management Drivers. NOTE: All of the following commands that are entered in a shell prompt are case-sensitive. 1 Using SCO/UnixWare's package utility: * Open a shell prompt * Type" scoadmin and press Enter * Click Application Installer * Click to view the diskette or CD ROM (for example DISK_A or CD-ROM_1) * Install the package that gets displayed. 2 Interactive installation: * Open a shell prompt * If installing from a diskette, type: pkgadd -d diskette1 * If installing from CD ROM, type: pkgadd -d cdrom1 * Follow the directions that appear on the screen. 3 Non-interactive installation: * Open a shell prompt * If installing from a diskette, type: pkgadd -d diskette1 -q -p -n uw7advmg * If installing from a CD ROM, type: pkgadd -d cdrom1 -q -p -n uw7advmg * Follow the directions that appear on the screen. There are two methods you can choose from when removing the SCO/UnixWare System Management Drivers. 1 For an interactive removal of the drivers: * Open a shell prompt * Type: pkgrm uw7advmg 2 For a non-interactive removal of the drivers: * Open a shell prompt * Type: pkgrm -n uw7advmg 4.0 Stopping the Netfinity Manager application program ------------------------------------------------------- If the Netfinity Manager application program is already running on your Netfinity Server it must be stopped prior to installing any of these device drivers. The following examples show how to do this. For NT and OS/2: * Close any open Netfinity windows * Open a Command prompt * Type: NETFBASE SHUTDOWN For NetWare: * Unload the Netfinity Support Program For SCO UnixWare: * Open a shell prompt * Type: netfbase.exe SHUTDOWN (NOTE: This is a case-sensitive statement.) For more details on how to shutdown the Netfinity application please refer to the Netfinity documentation. 5.0 WEB Sites and Support Phone Number --------------------------------------- 5.1 IBM Support Web Site: http://www.pc.ibm.com/support 5.2 IBM Marketing eserver xSeries Web Site: http://www.pc.ibm.com/us/eserver/xseries 5.3 If you have any questions about this update, or problems applying the update go to the following Help Center World Telephone Numbers URL: http://www.pc.ibm.com/qtechinfo/YAST-3P2QYL.html 6.0 Trademarks and Notices --------------------------- The following terms are trademarks of the Novell Corporation in the United States or other countries or both: Novell NetWare The following terms are trademarks of the Microsoft Corporation in the United States or other countries or both: Windows Windows NT Windows 2000 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: OS/2 Netfinity The following terms are trademarks of Santa Cruz Operation, Inc. in the United States or other countries or both: SCO UnixWare 7.0 Disclaimer --------------------------- 7.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 7.2 Note to Government Users Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.