Patch Name: PHSS_24986

Patch Description: s700_800 10.20 OV OB4.00 patch - SSEA packet

Creation Date: 01/10/29

Post Date:  01/10/31

Hardware Platforms - OS Releases:
	s700: 10.20
	s800: 10.20

Products:
	OmniBackII A.04.00

Filesets:
	OMNIBACK-II.OMNI-SSEA-P,A.04.00

Automatic Reboot?: No

Status: General Superseded

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_24986

Symptoms:
	PHSS_24986:
	Id = HSLco27782, SR: H555005757
	    SSEA Integration backup fails with an error:

	      "[Major] From: SSEA@<hostname> ""  Time: <time>
	         File system <path> could not be mounted
	         to <path>. ([16] Device busy).

	Id = HSLco28452, SR: H555006026
	    SSEA Integration backup fails with an error:

	      "[Major] From: SSEA@<hostname> ""  Time: <time>
	         Volume group /dev/<vg-name> could not be
	         activated.

	Id = NSMex04611, SR: H555006245
	    SSEA Integration backup fails with an error:

	      "[Critical] From: SSEA@<hostname> ""  Time:<time>
	         Unexpected close reading message from the agent
	         on the Backup System. (Unknown internal error.)

Defect Description:
	PHSS_24986:
	Id = HSLco27782
	    Session fails when backup system is left enabled,
	    SSEA_PRESERVE_MOUNTPOINTS is set to 1 in .omnirc
	    file and backup is restarted.

	Resolution:
	    Mountpoint is rechecked becouse it can change.

	Id = HSLco28452
	    If the volume group is located in a cluster on the
	    application side, it is not possible to activate
	    this volume group in "rw" mode on the backup side.

	Resolution:
	    By default volume group on the backup side is activated
	    in read only mode, unless the "Enable the backup system
	    in read/write mode" option is set for the backup.

	Id = NSMex04611
	    Because of the large number of backup volumes agent and
	    backup session manager lost connection to the ssea on
	    the application side in the middle of resolve function.

	Resolution:
	    Buffer concatenation is fixed.

	    Part of SSPUX400_004.

SR:
	H555006245 H555006026 H555005757

Patch Files:
	/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.04.00/
		packet.Z
	/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.04.00/
		packet.Z
	/opt/omni/databases/vendor/ssea/sun/sparc/solaris-7/A.04.00/
		packet.Z

what(1) Output:
	/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.04.00/
		packet.Z:
		None
	/opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.04.00/
		packet.Z:
		None
	/opt/omni/databases/vendor/ssea/sun/sparc/solaris-7/A.04.00/
		packet.Z:
		None

cksum(1) Output:
	2289704829 472427 /opt/omni/databases/vendor/ssea/hp/s800/
		hp-ux-1020/A.04.00/packet.Z
	947304901 472697 /opt/omni/databases/vendor/ssea/hp/s800/
		hp-ux-11/A.04.00/packet.Z
	2494510309 220271 /opt/omni/databases/vendor/ssea/sun/sparc/
		solaris-7/A.04.00/packet.Z

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies: None

Supersedes: None

Equivalent Patches:
	PHSS_24987:
	s700: 11.00 11.11 11.20
	s800: 11.00 11.11 11.20

Patch Package Size: 1200 KBytes

Installation Instructions:
	Please review all instructions and the Hewlett-Packard
	SupportLine User Guide or your Hewlett-Packard support terms
	and conditions for precautions, scope of license,
	restrictions, and, limitation of liability and warranties,
	before installing this patch.
	------------------------------------------------------------
	1. Back up your system before installing a patch.

	2. Login as root.

	3. Copy the patch to the /tmp directory.

	4. Move to the /tmp directory and unshar the patch:

		cd /tmp
		sh PHSS_24986

	5a. For a standalone system, run swinstall to install the
	    patch:

		swinstall -x autoreboot=true -x match_target=true \
			-s /tmp/PHSS_24986.depot

	By default swinstall will archive the original software in
	/var/adm/sw/patch/PHSS_24986.  If you do not wish to retain a
	copy of the original software, you can create an empty file
	named /var/adm/sw/patch/PATCH_NOSAVE.

	WARNING: If this file exists when a patch is installed, the
	         patch cannot be deinstalled.  Please be careful
		 when using this feature.

	It is recommended that you move the PHSS_24986.text file to
	/var/adm/sw/patch for future reference.

	To put this patch on a magnetic tape and install from the
	tape drive, use the command:

		dd if=/tmp/PHSS_24986.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
	PHSS_24986:
	NOTE!
	This patch has to be installed on the Installation
	Server host.

	The OB2 SSEA agent must be redistributed to the SSEA
	client system(s) after the installation of the patch
	in order to get the fixes into effect.

	For distribution of the SSEA agent, refer to
	the OmniBackII Installation guide.


	Patch includes the following Site Specific Patches:
	   SSPUX400_004