Patch Name: PHSS_24986 Patch Description: s700_800 10.20 OV OB4.00 patch - SSEA packet Creation Date: 01/10/29 Post Date: 01/10/31 Hardware Platforms - OS Releases: s700: 10.20 s800: 10.20 Products: OmniBackII A.04.00 Filesets: OMNIBACK-II.OMNI-SSEA-P,A.04.00 Automatic Reboot?: No Status: General Superseded Critical: No Path Name: /hp-ux_patches/s700_800/10.X/PHSS_24986 Symptoms: PHSS_24986: Id = HSLco27782, SR: H555005757 SSEA Integration backup fails with an error: "[Major] From: SSEA@<hostname> "" Time: <time> File system <path> could not be mounted to <path>. ([16] Device busy). Id = HSLco28452, SR: H555006026 SSEA Integration backup fails with an error: "[Major] From: SSEA@<hostname> "" Time: <time> Volume group /dev/<vg-name> could not be activated. Id = NSMex04611, SR: H555006245 SSEA Integration backup fails with an error: "[Critical] From: SSEA@<hostname> "" Time:<time> Unexpected close reading message from the agent on the Backup System. (Unknown internal error.) Defect Description: PHSS_24986: Id = HSLco27782 Session fails when backup system is left enabled, SSEA_PRESERVE_MOUNTPOINTS is set to 1 in .omnirc file and backup is restarted. Resolution: Mountpoint is rechecked becouse it can change. Id = HSLco28452 If the volume group is located in a cluster on the application side, it is not possible to activate this volume group in "rw" mode on the backup side. Resolution: By default volume group on the backup side is activated in read only mode, unless the "Enable the backup system in read/write mode" option is set for the backup. Id = NSMex04611 Because of the large number of backup volumes agent and backup session manager lost connection to the ssea on the application side in the middle of resolve function. Resolution: Buffer concatenation is fixed. Part of SSPUX400_004. SR: H555006245 H555006026 H555005757 Patch Files: /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.04.00/ packet.Z /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.04.00/ packet.Z /opt/omni/databases/vendor/ssea/sun/sparc/solaris-7/A.04.00/ packet.Z what(1) Output: /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-1020/A.04.00/ packet.Z: None /opt/omni/databases/vendor/ssea/hp/s800/hp-ux-11/A.04.00/ packet.Z: None /opt/omni/databases/vendor/ssea/sun/sparc/solaris-7/A.04.00/ packet.Z: None cksum(1) Output: 2289704829 472427 /opt/omni/databases/vendor/ssea/hp/s800/ hp-ux-1020/A.04.00/packet.Z 947304901 472697 /opt/omni/databases/vendor/ssea/hp/s800/ hp-ux-11/A.04.00/packet.Z 2494510309 220271 /opt/omni/databases/vendor/ssea/sun/sparc/ solaris-7/A.04.00/packet.Z Patch Conflicts: None Patch Dependencies: None Hardware Dependencies: None Other Dependencies: None Supersedes: None Equivalent Patches: PHSS_24987: s700: 11.00 11.11 11.20 s800: 11.00 11.11 11.20 Patch Package Size: 1200 KBytes Installation Instructions: Please review all instructions and the Hewlett-Packard SupportLine User Guide or your Hewlett-Packard support terms and conditions for precautions, scope of license, restrictions, and, limitation of liability and warranties, before installing this patch. ------------------------------------------------------------ 1. Back up your system before installing a patch. 2. Login as root. 3. Copy the patch to the /tmp directory. 4. Move to the /tmp directory and unshar the patch: cd /tmp sh PHSS_24986 5a. For a standalone system, run swinstall to install the patch: swinstall -x autoreboot=true -x match_target=true \ -s /tmp/PHSS_24986.depot By default swinstall will archive the original software in /var/adm/sw/patch/PHSS_24986. If you do not wish to retain a copy of the original software, you can create an empty file named /var/adm/sw/patch/PATCH_NOSAVE. WARNING: If this file exists when a patch is installed, the patch cannot be deinstalled. Please be careful when using this feature. It is recommended that you move the PHSS_24986.text file to /var/adm/sw/patch for future reference. To put this patch on a magnetic tape and install from the tape drive, use the command: dd if=/tmp/PHSS_24986.depot of=/dev/rmt/0m bs=2k Special Installation Instructions: PHSS_24986: NOTE! This patch has to be installed on the Installation Server host. The OB2 SSEA agent must be redistributed to the SSEA client system(s) after the installation of the patch in order to get the fixes into effect. For distribution of the SSEA agent, refer to the OmniBackII Installation guide. Patch includes the following Site Specific Patches: SSPUX400_004