Patch Name: PHSS_12503

Patch Description: s700_800 10.10 MeasureWare C.00.01 alarm problem patch

Creation Date: 97/09/29

Post Date:  97/10/08

Hardware Platforms - OS Releases:
	s700: 10.10
	s800: 10.10

Products:
	MeasureWare C.00.01

Filesets:
	MeasureWare.MWA

Automatic Reboot?: No

Status: General Release

Critical: No

Path Name: /hp-ux_patches/s700_800/10.X/PHSS_12503

Symptoms:
	PHSS_12503:
	1. MeasureWare cannot send alarms to PerfView on a
	   multi-homed system when one of the ip's is unreachable
	   (as in a ServiceGuard installation).

Defect Description:
	PHSS_12503:
	1. Added code to libept to verify that the server is
	   listening prior to adding it to the list of servers that
	   is returned to the caller.

SR:
	D500328401

Patch Files:
	/opt/perf/bin/agdbserver
	/opt/perf/bin/agsysdb
	/opt/perf/bin/alarmgen
	/opt/perf/bin/breakout
	/opt/perf/bin/mwaget
	/opt/perf/bin/perflbd
	/opt/perf/bin/rep_server
	/opt/perf/bin/utilengine

what(1) Output:
	/opt/perf/bin/agdbserver:
		agdbserver     C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/agsysdb:
		agsysdb        C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/alarmgen:
		alarmgen       C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/breakout:
		breakout       C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/mwaget:
		mwaget         C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/perflbd:
		perflbd        C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/rep_server:
		rep_server     C.00.02     09/10/97 HP-UX 10.10 =*=
	/opt/perf/bin/utilengine:
		utilengine     C.00.02     09/10/97 HP-UX 10.10 =*=

cksum(1) Output:
	3977857555 603179 /opt/perf/bin/agdbserver
	2153226438 574521 /opt/perf/bin/agsysdb
	199550815 876381 /opt/perf/bin/alarmgen
	833088157 543974 /opt/perf/bin/breakout
	3310348543 494468 /opt/perf/bin/mwaget
	387995226 902767 /opt/perf/bin/perflbd
	3861867154 1074380 /opt/perf/bin/rep_server
	353260780 716434 /opt/perf/bin/utilengine

Patch Conflicts: None

Patch Dependencies: None

Hardware Dependencies: None

Other Dependencies: None

Supersedes: None

Equivalent Patches:
	PHSS_12504:
	s700: 10.20
	s800: 10.20

	PHSS_12505:
	s800: 10.30

Patch Package Size: 5720 KBytes

Installation Instructions:
	Please review all instructions and the Hewlett-Packard
	SupportLine User Guide or your Hewlett-Packard support terms
	and conditions for precautions, scope of license,
	restrictions, and, limitation of liability and warranties,
	before installing this patch.
	------------------------------------------------------------
	1. Back up your system before installing a patch.

	2. Login as root.

	3. Copy the patch to the /tmp directory.

	4. Move to the /tmp directory and unshar the patch:

		cd /tmp
		sh PHSS_12503

	5a. For a standalone system, run swinstall to install the
	    patch:

		swinstall -x autoreboot=true -x match_target=true \
			-s /tmp/PHSS_12503.depot

	5b. For a homogeneous NFS Diskless cluster run swcluster on the
	    server to install the patch on the server and the clients:

		swcluster -i -b

	    This will invoke swcluster in the interactive mode and
	    force all clients to be shut down.

	    WARNING: All cluster clients must be shut down prior to the
		     patch installation.  Installing the patch while the
		     clients are booted is unsupported and can lead to
		     serious problems.

	    The swcluster command will invoke an swinstall session in which
	    you must specify:

		alternate root path  -  default is /export/shared_root/OS_700
		source depot path    -  /tmp/PHSS_12503.depot

	    To complete the installation, select the patch by choosing
	    "Actions -> Match What Target Has" and then "Actions -> Install"
	    from the Menubar.

	5c. For a heterogeneous NFS Diskless cluster:

		- run swinstall on the server as in step 5a to install
		  the patch on the cluster server.

		- run swcluster on the server as in step 5b to install
		  the patch on the cluster clients.

	By default swinstall will archive the original software in
	/var/adm/sw/patch/PHSS_12503.  If you do not wish to retain a
	copy of the original software, you can create an empty file
	named /var/adm/sw/patch/PATCH_NOSAVE.

	Warning: If this file exists when a patch is installed, the
	         patch cannot be deinstalled.  Please be careful
		 when using this feature.

	It is recommended that you move the PHSS_12503.text file to
	/var/adm/sw/patch for future reference.

	To put this patch on a magnetic tape and install from the
	tape drive, use the command:

		dd if=/tmp/PHSS_12503.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
	After installation, you will need to restart MeasureWare
	server processes by typing the command:
	'/opt/perf/bin/mwa start server'.