Patch Name:  PHSS_10876

Patch Description: s700_800 10.20 dtgreet and dtsession point patch

Creation Date: 97/04/25

Post Date:  97/04/28

Repost: 97/05/13
        PHSS_10876 has PHSS_9803 as a patch dependency.
        Unfortunately this is not documented.  Hence the repost.
        The actual patch bits were not altered.  Sites
        having the patch installed should not update to the
        reposted version.

Hardware Platforms - OS Releases:
        s700: 10.20
        s800: 10.20

Products: N/A

Filesets:
        CDE.CDE-RUN CDE.CDE-PAM

Automatic Reboot?: No

Status: Special Superseded

Critical: No

Path Name:  /hp-ux_patches/s700_800/10.X/PHSS_10876

Symptoms:
        PHSS_10876:
        1) Dtgreet hangs trying to display to xterminal without CDE
           fonts.
        2) cde:trusted system:screenlock: unlock by root seen as
           unsuccessful try
        3) CDE:Trusted system:root can't unlock screen lock
        4) Possibility of disableing user accounts on trusted
           system by screen lock
        5) CDE screen locker doesn't use DCE authentication to
           unlock the screen

Defect Description:
        PHSS_10876:
        1) Dtgreet hangs trying to display to xterminal without CDE
           fonts.
        2) cde:trusted system:screenlock: unlock by root seen as
           unsuccessful try
        3) CDE:Trusted system:root can't unlock screen lock
        4) Possibility of disableing user accounts on trusted
           system by screen lock
        5) CDE screen locker doesn't use DCE authentication to
           unlock the screen

SR:
        5003349738 5003356295 5003356287 5003356303 5003352930

Patch Files:
        /usr/lib/security/libpam_unix.1
        /usr/dt/bin/dtgreet
        /usr/dt/bin/dtsession

what(1) Output:
        /usr/lib/security/libpam_unix.1:
                X Window System, Version 11 R6+ HP-UX B.10.20.970423
                         +O2
                (build date: Wed Apr 23 15:48:42 PDT 1997)
        /usr/dt/bin/dtgreet:
                X Window System, Version 11 R6+ HP-UX B.10.20.00 Mar
                         1997 Patch Release
                (build date: Wed Feb 26 17:16:10 PST 1997)
                dtgreet: $Revision: 1.5 $
        /usr/dt/bin/dtsession:
                X Window System, Version 11 R6+ HP-UX B.10.20.00 Mar
                         1997 Patch C Releasee
                (build date: Fri Apr 25 09:38:58 PDT 1997)
                dtsession: $Revision: 2.0 $

cksum(1) Output:
        123989032 90298 /usr/lib/security/libpam_unix.1
        117590794 86016 /usr/dt/bin/dtgreet
        3317115576 176128 /usr/dt/bin/dtsession

Patch Conflicts: None

Patch Dependencies:  None

Hardware Dependencies:  None

Other Dependencies:  None

Supersedes:  None

Equivalent Patches: None

Patch Package Size:  400 Kbytes

Installation Instructions:
        Please review all instructions and the Hewlett-Packard
        SupportLine User Guide or your Hewlett-Packard support terms
        and conditions for precautions, scope of license,
        restrictions, and, limitation of liability and warranties,
        before installing this patch.
        ------------------------------------------------------------
        1. Back up your system before installing a patch.

        2. Login as root.

        3. Copy the patch to the /tmp directory.

        4. Move to the /tmp directory and unshar the patch:

                cd /tmp
                sh PHSS_10876

        5a. For a standalone system, run swinstall to install the
            patch:

                swinstall -x autoreboot=true -x match_target=true \
                        -s /tmp/PHSS_10876.depot

        5b. For a homogeneous NFS Diskless cluster run swcluster on the
            server to install the patch on the server and the clients:

                swcluster -i -b

            This will invoke swcluster in the interactive mode and
            force all clients to be shut down.

            WARNING: All cluster clients must be shut down prior to the
                     patch installation.  Installing the patch while the
                     clients are booted is unsupported and can lead to
                     serious problems.

            The swcluster command will invoke an swinstall session in which
            you must specify:

                alternate root path  -  default is /export/shared_root/OS_700
                source depot path    -  /tmp/PHSS_10876.depot

            To complete the installation, select the patch by choosing
            "Actions -> Match What Target Has" and then "Actions -> Install"
            from the Menubar.

        5c. For a heterogeneous NFS Diskless cluster:

                - run swinstall on the server as in step 5a to install
                  the patch on the cluster server.

                - run swcluster on the server as in step 5b to install
                  the patch on the cluster clients.

        By default swinstall will archive the original software in
        /var/adm/sw/patch/PHSS_10876.  If you do not wish to retain a
        copy of the original software, you can create an empty file
        named /var/adm/sw/patch/PATCH_NOSAVE.

        Warning: If this file exists when a patch is installed, the
                 patch cannot be deinstalled.  Please be careful
                 when using this feature.

        It is recommended that you move the PHSS_10876.text file to
        /var/adm/sw/patch for future reference.

        To put this patch on a magnetic tape and install from the
        tape drive, use the command:

                dd if=/tmp/PHSS_10876.depot of=/dev/rmt/0m bs=2k

Special Installation Instructions:
        It is recommended that patch PHSS_9803 is applied first.
        Please note:
           The CDE environment must not be running when this
           patch is installed.

           If it is, you will receive warnings that text files
           are busy.  SD will move these aside and place the
           new files in the appropriate location, but it is
           recomended that CDE first be shutdown prior to patch
           instalation.

        Requires the Periodic Patch PHSS_9803 to be installed
        first. Otherwise, you may receive warnings about
        unresolved external symbols.