SOFTPAQ NUMBER : SP30527 PART NUMBER : N/A FILE NAME : SP30527.exe TITLE : Extended Feature Supplement 5.68a for SCO OpenServer Release 5 VERSION : 5.68a LANGUAGE : English DIVISIONS : Systems CATEGORY : Drivers PRODUCTS AFFECTED: ProLiant ML310 G2 ProLiant ML330 G2 SCSI ProLiant ML330 G3 SCSI ProLiant ML350 G2 ProLiant ML350 G3 ProLiant ML350 G4 ProLiant ML350 G4p ProLiant ML370 G2 ProLiant ML370 G3 ProLiant ML370 G4 ProLiant DL380 G4 ProLiant DL380 G4 SAS ProLiant ML530 G2 ProLiant ML570 G2 CURRENT OPERATING SYSTEM SUPPORT: SCO OpenServer Release 5.0.7 Enterprise System SCO OpenServer Release 5.0.6a Enterprise System SCO OpenServer Release 5.0.6 Host System DISCLAIMER: Installing this software on OS versions or the ProLiant Servers other than those listed may result in unexpected behavior. Note: Intel(R) PRO/100 Network driver(eeE), Intel(R) PRO/1000 Network driver(eeG) and Broadcom Gigabit Ethernet Network driver(bcme) will not be installed by default during EFS installation. To install these drivers, run hpnicinstall command provided by EFS. For more details on this command, refer to hpnicinstall man page. Please check the HP products and services ProLiant Server OS Support Matrix at http://h10018.www1.hp.com/wwsolutions/sco/index-all.html/ for more detailed OS support information. SYSTEM CONFIGURATION: Any system running one of the listed Operating Systems. EFFECTIVE DATE: June 21, 2005 ELECTRONIC DISTRIBUTION ALLOWED: Yes SUPERSEDES: SP29050 DESCRIPTION: Creates five (5) diskettes containing the Extended Feature Supplement 5.68a for SCO OpenServer 5. This is a collection of device drivers that provides maximum performance with ProLiant hardware. It also includes several utilities to monitor and increase the performance of your ProLiant server. This EFS version contains the following device drivers and Utilities: - Broadcom NetXtreme BCM5700 series Gigabit Ethernet Controller Support - HP NC6770 Gigabit Server Adapter - HP NC7770 Gigabit Server Adapter - HP NC7771 Gigabit Server Adapter - HP NC7760 Embedded Gigabit Server Adapter - HP NC7761 Embedded Gigabit Server Adapter - HP NC7781 Embedded Gigabit Server Adapter - HP NC7782 Embedded Gigabit Server Adapter - HP NC1020 Gigabit Server Adapter - HP NC320T PCI Express Gigabit Server Adapter - Ethernet, Fast Ethernet, and Gigabit Controllers and Module Support - HP NC3120 Fast Ethernet NIC - HP NC3121 Fast Ethernet NIC - HP NC3122 Fast Ethernet NIC - HP NC3123 Fast Ethernet NIC - HP NC3131 Fast Ethernet NIC - HP NC3132 Fast Ethernet Module - HP NC3133 Fast Ethernet Module - HP NC3134 Fast Ethernet NIC - HP NC3135 Fast Ethernet Upgrade Module - HP NC3160 Fast Ethernet NIC - HP NC3161 Fast Ethernet NIC - HP NC3162 Fast Ethernet NIC - HP NC3163 Fast Ethernet NIC - HP NC6132 Gigabit Module - HP NC6133 Gigabit Module - HP NC6134 Gigabit NIC - HP NC6136 Gigabit Server Adapter - HP NC7131 Gigabit Server Adapter - HP NC7132 Gigabit Upgrade Module - HP Dual PCI-X NC6170 1000-SX Gigabit Server Adapter - HP Dual PCI-X NC7170 1000-T Gigabit Server Adapter - HP NC310F PCI-X Gigabit Server Adapter - NetFlex Controller Support - NetFlex-3/P Controller - NetFlex-3/E Controller - Netelligent Controller Support - Netelligent 10 T/2 PCI UTP/Coax Controller - Netelligent 10 T PCI UTP Controller - Netelligent 10/100 TX PCI UTP Controller - Netelligent Dual 10/100 TX PCI UTP Controller - Netelligent 10/100 TX Embedded UTP/Coax Controller - Netelligent 10/100 TX Embedded UTP/AUI Controller - Netelligent 10/100 TX Embedded UTP Controller - Ultra320 SCSI Support - HP Single Channel Ultra320 SCSI Host Bus Adapter G2 - HP 64Bit/133MHz Dual Channel Ultra320 SCSI Host Bus Adapter - Ultra3 SCSI Support - 64-bit/66-Mhz Dual Channel Wide Ultra3 SCSI Adapter - 64-bit/66-Mhz Single Channel Wide Ultra3 SCSI Adapter - SCSI-2 Support - 32-Bit Fast-SCSI-2 Controller Card - 32-Bit Fast-Wide SCSI - 2/ E Controller Card - 32-Bit Fast-Wide SCSI - 2/ P Controller Card - 32-Bit Fast-Wide Ultra SCSI Controller card - Dual Channel Wide-Ultra SCSI-3 Controller card - 64-Bit Dual Channel Wide-Ultra-2 SCSI Controller card - SCSI-2 support also includes driver support for the integrated SCSI-2 options port on the SystemPro/XL Server - Drive Array Support - Intelligent Drive Array Controller - IDA-Expansion Array Controller - IDA-2 Array Controller - Integrated Smart Array Controller - RAID LC2 Controllers - SMART-2/E Array Controller - SMART-2/P Array Controller - SMART-2/SL Array Controller - SMART-2/DH Array Controller - Smart Array 3100ES Controller - Smart Array 3200 Controller - Smart Array 221 controller - Smart Array 4200 Controller - Smart Array 431 Controller - Smart Array 4250ES Controller - Smart Array 5300 Controller - Smart Array 532 Controller - Smart Array 5312 Controller - Smart Array 5i Controller - Smart Array 641 Controller - Smart Array 642 Controller - Smart Array 6402 Controller - Smart Array 6404 Controller - Smart Array 6i Controller - Smart Array P600 Controller - Smart Array Cluster Storage - Fibre-Channel Drive Array Support - Fibre Channel Host Controller/E - Fibre Channel Host Controller/P - StorageWorks 64-Bit/66-Mhz Fibre Host Bus Adapter - Remote Insight Support - Remote Insight Board/PCI Version 2.00 - Remote Insight Lights-Out Edition - Remote Insight Lights-Out Edition II - hp ProLiant Advanced System Management Driver - Intelligent Drive Array Support - Boot-Time Loadable Drivers - Standby Server Daemon - SCSI-2 Management Utility - hp ProLiant IDA Diagnostics Utility - hp ProLiant CLAD Diagnostics Utility - hp ProLiant CASA Diagnostics Utility - hp ProLiant CISS Diagnostics Utility - System Monitor Utility - Ultra Diagnostics Utility - IMD Idle Screen Service Utility - Integrated Management Log Utility New Features in EFS Version 5.68a for SCO OpenServer 5 - Support added for HP ProLiant ML350 G4p (SCSI version) - Support added for HP ProLiant DL380 G4 SAS - Support added for HP Smart Array P600 controller - Support added for MSA 50 (Serial Attached SCSI External Storage Enclosure) - Support added for next generation Intel Processors HOW TO USE: 1. Download the SoftPaq to a directory on your hard drive. The file downloaded is a self-extracting executable with a filename based on the SoftPaq Number. 2. Self-extracting executable will launch Quick Release Sector Transfer utility (QRST5) that helps you in creating EFS diskettes. Follow the on-screen instructions. 3. If you have extracted and saved the following files in a directory for later use, you may create EFS floppies by following the procedure given in steps 4 till 10 below. SP30527._01 SP30527._02 SP30527._03 SP30527._04 SP30527._05 QRST5.EXE README.TXT 4. Browse or change to the directory containing the files listed in step 3. Obtain 5 DOS formatted 1.44 MB diskettes IMPORTANT: Only 1.44 MB DOS formatted diskettes can be used, other types of media cannot be substituted. 5. Execute the QRST5.EXE program: QRST5 [ENTER] 6. When the "Select Diskettes in this set" prompt appears, choose the highlighted default selection "Do ALL of the diskettes in this set" by pressing ENTER. 7. The "Enter Destination Drive" prompt is given. Either A or B will be included in the prompt depending on where your 3.5 inch diskette drive is located. If the drive shown in the prompt is not the one you wish to use, change the value by pressing either A or B. At this point, you can optionally print a label (if your printer is attached) by pressing F9. Press ENTER to accept the diskette drive letter. The same screen will reappear. Press ENTER again to extract and decompress the diskette image. 8. The "Ready to copy diskette" prompt appears. It is asking for one 1.44 MB diskette. Verify that you have a formatted 1.44 MB diskette in the appropriate disk drive and press ENTER to begin diskette creation. 9. A counter box will be displayed during creation showing status. The number of cylinders will count up to 80 on a 1.44 MB floppy drive. 10. Repeat from step 7 until all five diskettes have been created. 11. When QRST5 has completed, it will exit back to DOS. At this point, the EFS 5.68a diskettes have been created and are ready to use. ---------- IMPORTANT: ---------- Please read all information in the README.TXT file on the documentation diskette before installing the EFS. NOTE: You can verify that you have valid EFS 5.68a diskettes by using the UNIX sum -r command: sum -r /dev/fd0 The following sum values should be displayed: BTLD : 08133 EFS DISK1: 12591 EFS DISK2: 51290 EFS DISK3: 29115 The Documentation diskette is not shown here with its checksum. Copyright (c) 2003-2005 Hewlett-Packard Development Company, L.P. Copyright (c) 1991-2005, The SCO Group, Inc. All rights reserved Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies.