PROPOSED TITLE: eFix IC31780 - ERRONEOUS REDUNDANT POWER SUPPLY MESSAGES FOR NETFINITY AND eSERVER X-SERIES UNDER NETFINITY DIRECTOR 2.2.1 WITH UM SERVER EXTENSION CHIP KILL/FUEL GUAGE 2.21 SECURITY: Unclassified VERIFICATION: Director Product Engineering (Raymond Cook III) AUTHOR: Raymond Cook III Director Product Engineering Raymond Cook III/Raleigh/IBM@IBMUS CURRENT AS OF: 08/28/01 GEO/COUNTRY: World Wide PROACTIVE EMAIL:No (Below is what would publish on the Web) Symptom: Erroneous redundant power supply messages when stopping and restarting the Director Support Program Service or rebooting the system. The following error messages are logged: Warning - Regained redundancy: the system is operating with redundancy Warning - Regained normal current: the system is operating below maximum specifications Critical- Power redundancy has been restored Affected configurations: Operating System: Windows 2000 Server Windows 2000 Professional Windows NT 4.0 Server Windows NT 4.0 Workstation Application: UM Server Extensions Chip Kill/Fuel Guage 2.20 UM Server Extensions Chip Kill/FUel Guage 2.21 Solution: Apply eFix IC31780 available from http://www.pc.ibm.com/support Detailed information regarding fix or proposed fix Files Replaced or Added by this Patch: %NFD_HOME%\bin 08/28/2001 12:09p 59Kb ASMAgent.exe 08/28/2001 02:10p 1054Kb CKillAgent.exe Additional information Any information that does not fit the categories above. (optional)